EUVIMEDEUVIMED entdecken
Crossref

D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program

Eric Salazar, Kristi J Smock, Taryn Cazzolli, Jeffrey S Dlott, Nathan Lickteig, Thomas A Long, Joseph J Mulvey, Morayma R Gil, Marian Rollins-Raval, Jun Teruya, Oksana Volod, Chance A Walker und 3 weitere

Seminars in Thrombosis and Hemostasis · 2026-11 · 52 (08) · 975-981

DOI: 10.1055/a-2803-3165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Seminars in Thrombosis and Hemostasis, online erschienen am 06.03.2026. Verfasst von Eric Salazar und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Laboratory Medicine, UT Health San Antonio, San Antonio, Texas, United States. Hauptthemen laut MEDLINE: Fibrin Fibrinogen Degradation Products, Laboratory Proficiency Testing. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measurement of D-dimer, a fibrin degradation product, is crucial for diagnosing thrombotic and fibrinolytic conditions. Despite its expanding utility, D-dimer testing faces challenges due to varying assay methodologies and nonstandardized reporting. To understand D-dimer reporting practices, the College of American Pathologists Hemostasis and Thrombosis Committee analyzed proficiency testing data from D-dimer surveys conducted between 2020 and 2023 across multiple laboratories. The data demonstrate that laboratories commonly report units that differ from the assay package insert when reporting their proficiency testing results. We sought to assess variability in reporting practices and opportunities for improvement in D-dimer reporting amongst participants. To accomplish this, we harmonized all D-dimer results to ng/mL fibrinogen equivalent units from one distributed sample and assessed distinct populations of entries per instrument/reagent combination. Notable trends emerged from this analysis. Data from laboratories using the same instrument/reagent combinations clustered around different means, suggesting issues with unit reporting and/or conversion. Entries reported in mg/L or ug/mL D-dimer units commonly exhibited significant deviations from the dominant population. For one instrument/reagent combination, most reported values differed by approximately twice the certificate of analysis value. This analysis highlights potential issues with D-dimer reporting in proficiency testing. Whether these issues translate into issues with clinical D-dimer reporting requires further study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fibrin Fibrinogen Degradation ProductsLaboratory Proficiency TestingHumansUnited States

Substanzen

Fibrin Fibrinogen Degradation Productsfibrin fragment D

Autor:innen und Institutionen

  • Department of Pathology and Laboratory Medicine, UT Health San Antonio, San Antonio, Texas, United States.
  • Department of Pathology and ARUP Laboratories, University of Utah, Salt Lake City, Utah, United States.
  • The Department of Laboratory Medicine and Pathology, Mayo Clinic Jacksonville, Jacksonville, Florida, United States.
  • The Department of Pathology, University of New Mexico, Albuquerque, New Mexico, United States.
  • Department of Biostatistics, College of American Pathologists, Northfield, Illinois, United States.
  • The Department of Pathology, Montefiore Medical Center, Bronx, New York, United States.

Zitieren

APA

Salazar, E., Smock, K. J., Cazzolli, T., Dlott, J. S., Lickteig, N., Long, T. A., Mulvey, J. J., Gil, M. R., Rollins-Raval, M., Teruya, J., Volod, O., Walker, C. A., Wool, G. D., Zantek, N. D., & Goodwin Iv, A. J. (2026). D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program. Seminars in Thrombosis and Hemostasis, 52(08), 975-981. https://doi.org/10.1055/a-2803-3165

Vancouver

Salazar E, Smock KJ, Cazzolli T, Dlott JS, Lickteig N, Long TA, et al. D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program. Seminars in Thrombosis and Hemostasis. 2026;52(08):975-981. doi:10.1055/a-2803-3165

BibTeX
@article{Salazar2026,
  author = {Salazar, Eric and Smock, Kristi J and Cazzolli, Taryn and Dlott, Jeffrey S and Lickteig, Nathan and Long, Thomas A and Mulvey, Joseph J and Gil, Morayma R and Rollins-Raval, Marian and Teruya, Jun and Volod, Oksana and Walker, Chance A and Wool, Geoffrey D and Zantek, Nicole D and Goodwin Iv, Andrew J},
  title = {D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program},
  journal = {Seminars in Thrombosis and Hemostasis},
  year = {2026},
  volume = {52},
  number = {08},
  pages = {975--981},
  doi = {10.1055/a-2803-3165}
}
Kostenlos starten →