Simulation-Based Training for Endoscopic Internal Carotid Artery Injury Management: Performance and Confidence Outcomes Using a Live Porcine Model
Journal of Neurological Surgery Part B: Skull Base · 2026-12 · 87 (06) · 648-654
DOI: 10.1055/a-2798-8080 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neurological Surgery Part B: Skull Base, online erschienen am 09.02.2026. Verfasst von Camila S Dassi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, Federal University of São Paulo (UNIFESP), São PauloBrazil. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
To evaluate the educational outcomes of a structured simulation program using a live porcine model for internal carotid artery (ICA) injury management during endoscopic endonasal surgery, analyzing both objective and subjective participant data. This study included 80 surgeons with different levels of experience who participated, between 2021 and 2024, in a hands-on simulation course on ICA injury management. Demographic data, hemorrhage control time, and self-perceived technical confidence—assessed using a visual analog scale (VAS)—were collected before and after the training. Statistical analyses included normality tests, Mann–Whitney U test, Spearman correlation, and stepwise linear regression, with significance set at p < 0.05. Participants had a mean age of 38.8 ± 8.6 years. The mean hemorrhage control time was 106.5 ± 37.4 seconds. VAS confidence scores improved significantly from a mean of 1.94 (pretraining) to 8.50 (posttraining; p < 0.001), indicating a substantial gain in technical confidence. Regression analysis showed that a higher annual volume of endoscopic surgeries and greater experience in endoscopic surgery, measured in years (estimate: −2.71; p = 0.007; Spearman's ρ = − 0.308), were significantly associated with shorter hemorrhage control times. Prior training also had a marked impact, with participants who had undergone previous training achieving faster control (69.8 seconds vs. 110.6 seconds; p < 0.001), while specialty (neurosurgery vs. otolaryngology) showed no significant difference (p = 0.602). The simulation program demonstrated strong educational effectiveness, significantly improving technical performance and self-confidence. These findings support the integration of high-fidelity simulation programs into residency and fellowship curricula for skull base surgery.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology, Federal University of São Paulo (UNIFESP), São PauloBrazil.
- Department of Otolaryngology, Hospital Edmundo Vasconcelos, São PauloBrazil.
- Department of ENT, Head and Neck and Skull Base Surgery at Rio de Janeiro State University, Rio de JaneiroBrazil.
- Department of ENT and Skull Base Surgery at Policlinica de Botafogo, Rio de JaneiroBrazil.
ORCID-Profile: Camila S Dassi
Zitieren
APA
Dassi, C. S., Tepedino, M. S., Ferrão, A. C., Stamm, A., Justo, T. M., & Pezato, R. (2026). Simulation-Based Training for Endoscopic Internal Carotid Artery Injury Management: Performance and Confidence Outcomes Using a Live Porcine Model. Journal of Neurological Surgery Part B: Skull Base, 87(06), 648-654. https://doi.org/10.1055/a-2798-8080
Vancouver
Dassi CS, Tepedino MS, Ferrão AC, Stamm A, Justo TM, Pezato R. Simulation-Based Training for Endoscopic Internal Carotid Artery Injury Management: Performance and Confidence Outcomes Using a Live Porcine Model. Journal of Neurological Surgery Part B: Skull Base. 2026;87(06):648-654. doi:10.1055/a-2798-8080
BibTeX
@article{Dassi2026,
author = {Dassi, Camila S and Tepedino, Miguel S and Ferrão, Ana C and Stamm, Aldo and Justo, Thais M and Pezato, Rogério},
title = {Simulation-Based Training for Endoscopic Internal Carotid Artery Injury Management: Performance and Confidence Outcomes Using a Live Porcine Model},
journal = {Journal of Neurological Surgery Part B: Skull Base},
year = {2026},
volume = {87},
number = {06},
pages = {648--654},
doi = {10.1055/a-2798-8080}
}
EUVIMED