EUVIMEDEUVIMED entdecken
Crossref

Influence of Individual Traits on Measurement Differences in Percent Body Fat

Meghan K Magee, Angela Miller, Jennifer B Fields, Andrew R Jagim, Brittanie Lockard, Debra Stroiney, Margaret T Jones iD

International Journal of Sports Medicine · 01.07.2026 · 47 (08) · 599-604

DOI: 10.1055/a-2785-7668 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Sports Medicine, erschienen am 01.07.2026. Verfasst von Meghan K Magee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Health Sciences, Kent State University, Kent, USA. Hauptthemen laut MEDLINE: Absorptiometry, Photon, Plethysmography, Adipose Tissue, Body Composition.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AbstractThe purpose of the current study was to identify the influence of individual characteristics on differences in body fat percentage between air displacement plethysmography and dual-energy X-ray absorptiometry (change in body fat percentage) in 360 collegiate student-athletes. Body fat percentage was obtained from air displacement plethysmography and dual-energy X-ray absorptiometry. A 2 (sex)×3 (Brozek body fat percentage, Siri body fat percentage, and dual-energy x-ray absorptiometry body fat percentage) analysis of variance was used to evaluate the difference between the body fat percentages obtained from air displacement plethysmography and dual-energy x-ray absorptiometry in men and women. The agreement between air displacement plethysmography and dual-energy X-ray absorptiometry was evaluated via Bland–Altman plot and linear regression. Multiple linear regression was used to identify the influence of sex, race, height, and body mass on the change in body fat percentages. Dual-energy X-ray absorptiometry yielded greater body fat percentages in both men (4.8±2.8; p < 0.001) and women (2.2±2.9; p < 0.001) compared to air displacement plethysmography measurements. Proportional and systematic biases were observed between air displacement plethysmography and dual-energy X-ray absorptiometry. Race, height, and mass were significant predictors of the body fat percentage difference between air displacement plethysmography and dual-energy X-ray absorptiometry (R 2=0.445, p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Absorptiometry, PhotonPlethysmographyAdipose TissueBody CompositionHumansMaleFemaleYoung AdultSex FactorsLinear ModelsAdolescentBody HeightBody Mass Index

Autor:innen und Institutionen

  • Health Sciences, Kent State University, Kent, USA.
  • Education, George Mason University, Fairfax, USA.
  • Nutritional Sciences, University of Connecticut, Storrs, USA.
  • Sports Medicine Research, Mayo Clinic Health System, La Crosse, USA.
  • Kinesiology, University of the Incarnate Word, San Antonio, USA.
  • Kinesiology, George Mason University, Fairfax, USA.

ORCID-Profile: Margaret T Jones

Zitieren

APA

Magee, M. K., Miller, A., Fields, J. B., Jagim, A. R., Lockard, B., Stroiney, D., & Jones, M. T. (2026). Influence of Individual Traits on Measurement Differences in Percent Body Fat. International Journal of Sports Medicine, 47(08), 599-604. https://doi.org/10.1055/a-2785-7668

Vancouver

Magee MK, Miller A, Fields JB, Jagim AR, Lockard B, Stroiney D, et al. Influence of Individual Traits on Measurement Differences in Percent Body Fat. International Journal of Sports Medicine. 2026;47(08):599-604. doi:10.1055/a-2785-7668

BibTeX
@article{Magee2026,
  author = {Magee, Meghan K and Miller, Angela and Fields, Jennifer B and Jagim, Andrew R and Lockard, Brittanie and Stroiney, Debra and Jones, Margaret T},
  title = {Influence of Individual Traits on Measurement Differences in Percent Body Fat},
  journal = {International Journal of Sports Medicine},
  year = {2026},
  volume = {47},
  number = {08},
  pages = {599--604},
  doi = {10.1055/a-2785-7668}
}
Kostenlos starten →