Liver Fat Quantification: Agreement and Reproducibility of Ultrasound-Derived Fat Fraction Measurements Using 5C1 and DAX Probes in Subjects Stratified by BMI
Ultraschall in der Medizin - European Journal of Ultrasound · 04.02.2026
DOI: 10.1055/a-2781-1698 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultraschall in der Medizin - European Journal of Ultrasound, erschienen am 04.02.2026. Verfasst von Ricarda Lamprecht-Bailer und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine 1 Gastroenterology Endocrinology and Pneumology, Erlangen University Hospital, Erlangen, Germany. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gesellschaft für Gastroenterologie in Bayern e.V..
Abstract (Originalsprache)
This study aimed to assess the agreement between the 5C1 and deep abdominal transducer (DAX) ultrasound probes when measuring ultrasound-derived fat fraction (UDFF) across different body mass index (BMI) categories and to evaluate the intra- and inter-observer reproducibility of liver fat measurements. In this prospective study 63 subjects (32 with BMI < 25 and 31 with BMI ≥ 25) underwent UDFF measurements. Two observers performed five measurements per subject using both probes (5C1 and DAX). Intra- and inter-observer reliability were assessed using intraclass correlation coefficients (ICC). Agreement between probes and observers was evaluated using Spearman correlation and Bland-Altman analysis, stratified by BMI subgroup. The intra- and inter-observer reliability of UDFF measurements were excellent, with no relevant systematic bias between observers or probes. The 5C1 and DAX probes showed strong correlations (r = 0.92 and 0.93). In normal-weight subjects, differences between probes were minimal, with limits of agreement (LoA) of approximately ±2%. In subjects with BMI ≥ 25, the mean differences between probes were low (up to 2.6%), but the limits of agreement were wider (–8% to +13%), comparable to the inter-observer variability. UDFF measurements with both the 5C1 and DAX probes showed consistently high reliability across BMI categories. Although variability increased with a higher BMI and liver fat, no systematic bias was observed, and both probes performed comparably. These findings support their interchangeable use in clinical settings. Validation against a reference standard is warranted to assess accuracy in challenging patient populations.
Autor:innen und Institutionen
- Department of Medicine 1 Gastroenterology Endocrinology and Pneumology, Erlangen University Hospital, Erlangen, Germany.
Förderung
- Gesellschaft für Gastroenterologie in Bayern e.V.
Zitieren
APA
Lamprecht-Bailer, R., Fischer, S., Haberkamp, S., Schmid, J., Neurath, M. F., Zundler, S., & Klett, D. (2026). Liver Fat Quantification: Agreement and Reproducibility of Ultrasound-Derived Fat Fraction Measurements Using 5C1 and DAX Probes in Subjects Stratified by BMI. Ultraschall in der Medizin - European Journal of Ultrasound. https://doi.org/10.1055/a-2781-1698
Vancouver
Lamprecht-Bailer R, Fischer S, Haberkamp S, Schmid J, Neurath MF, Zundler S, et al. Liver Fat Quantification: Agreement and Reproducibility of Ultrasound-Derived Fat Fraction Measurements Using 5C1 and DAX Probes in Subjects Stratified by BMI. Ultraschall in der Medizin - European Journal of Ultrasound. 2026. doi:10.1055/a-2781-1698
BibTeX
@article{LamprechtBailer2026,
author = {Lamprecht-Bailer, Ricarda and Fischer, Sarah and Haberkamp, Sophie and Schmid, Jonas and Neurath, Markus F and Zundler, Sebastian and Klett, Daniel},
title = {Liver Fat Quantification: Agreement and Reproducibility of Ultrasound-Derived Fat Fraction Measurements Using 5C1 and DAX Probes in Subjects Stratified by BMI},
journal = {Ultraschall in der Medizin - European Journal of Ultrasound},
year = {2026},
doi = {10.1055/a-2781-1698}
}
EUVIMED