EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Safety and efficacy of fully-covered self-expandable metal stent placement for refractory stomal stenosis

Ahamed A Khalyfa iD, Navkiran K Randhawa, Rahil Desai iD, Mahnoor Inam, Varshita Goduguchinta, Kamran Ayub

Endoscopy International Open · 27.01.2026 · 14 (CP)

DOI: 10.1055/a-2777-8929 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 27.01.2026. Verfasst von Ahamed A Khalyfa und 5 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology, University of Iowa Health Care, Iowa City, United States. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stomas, critical in managing various gastrointestinal conditions, can lead to complications like stomal stenosis, affecting 2% to 15% of patients and causing significant morbidity. Traditional treatments such as balloon dilation and surgical revisions often fail to provide lasting relief. This study investigated a novel, minimally invasive approach using fully-covered self-expanding metal stents (FCSEMSs) to address refractory stomal stenosis effectively. Five patients with recurrent stomal strictures unresponsive to conventional treatments underwent stent placement. Etiologies included Crohn’s disease, ischemia, and post-surgical fibrosis. Stents were selected based on stricture characteristics, ranging from 10 to 16 mm in diameter and 6 to 10 cm in length. Technical success was defined as successful deployment without immediate complication; clinical success was defined as sustained symptom resolution during follow-up. Outcome measures included abdominal girth, pain reduction (visual analog scale), vomiting, and dietary tolerance. Follow-up periods ranged from 8 weeks to 6 months. All procedures were technically successful. Mean abdominal girth decreased from 114 ± 4.2 cm (range 108–119) to 103 ± 3.7 cm (range 99–108). Pain scores decreased from a mean of 8 ± 1.1 to 2 ± 1.2. Vomiting, bloating, and dietary tolerance improved in most patients. No stent migration or erosions/ulcer was observed during follow-up. Four patients had follow-up to 6 months without restenosis. One patient had restenosis with successful re-stenting within a 6-month follow-up period. FCSEMSs represent a safe and effective minimally invasive alternative for refractory stomal stenosis, with promising short-term outcomes.

Schlagwörter

Stichwörter der Autor:innen

Colorectal cancerEndoscopy Lower GI TractEndoscopy Upper GI TractInflammatory bowel diseaseMalignant stricturesStenting

Autor:innen und Institutionen

  • Gastroenterology, University of Iowa Health Care, Iowa City, United States.
  • Gastroenterology, Augusta University, Augusta, United States.
  • IM, Franciscan Health Olympia Fields, Olympia Fields, United States.
  • Gastroenterology, Southwest Gastroenterology, New Lenox, United States.
  • Franciscan Health Olympia Fields, Olympia Fields, United States.
  • Gastroenterology, Silver Cross Hospital, New Lenox, United States.

ORCID-Profile: Ahamed A Khalyfa, Rahil Desai

Zitieren

APA

Khalyfa, A. A., Randhawa, N. K., Desai, R., Inam, M., Goduguchinta, V., & Ayub, K. (2026). Safety and efficacy of fully-covered self-expandable metal stent placement for refractory stomal stenosis. Endoscopy International Open, 14(CP). https://doi.org/10.1055/a-2777-8929

Vancouver

Khalyfa AA, Randhawa NK, Desai R, Inam M, Goduguchinta V, Ayub K. Safety and efficacy of fully-covered self-expandable metal stent placement for refractory stomal stenosis. Endoscopy International Open. 2026;14(CP). doi:10.1055/a-2777-8929

BibTeX
@article{Khalyfa2026,
  author = {Khalyfa, Ahamed A and Randhawa, Navkiran K and Desai, Rahil and Inam, Mahnoor and Goduguchinta, Varshita and Ayub, Kamran},
  title = {Safety and efficacy of fully-covered self-expandable metal stent placement for refractory stomal stenosis},
  journal = {Endoscopy International Open},
  year = {2026},
  volume = {14},
  number = {CP},
  doi = {10.1055/a-2777-8929}
}
Kostenlos starten →