Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.03.2026. Verfasst von Hiroshi Kawakami und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Endoscopic biliary drainage (BD) is commonly performed in patients with perihilar biliary obstruction; however, the most appropriate method remains controversial. The plastic stent technique involves placing the tip of inside stent within the bile duct. Recently, the clinical outcomes of the inside and conventional plastic stents or the metal stent for the management of BD have been reported to be comparable in patients with preoperable/unresectable cholangiocarcinoma [ 1 ] [ 2 ] [ 3 ]. However, severe biliary strictures may not allow multiple inside stent placements, and another a replacement is occasionally difficult to advance through the biliary stricture, and involves a risk of migration. To overcome this limitation, we developed a 6 Fr inside biliary plastic stent ([ Fig. 1 ] a–d ). Multiple 6 Fr stents can be deployed simultaneously in a side-by-side fashion over the guidewire. Herein, we present patients treated successfully for perihilar BD using this new system. Fig. 1 a A novel 6 Fr inside biliary stent (9- and 12-cm length) and blue snare, and a 6-Fr pushing catheter system (190 cm in length, SILUX Co., Ltd, Saitama, Japan). b The tip of a 3 Fr inner tapered catheter and a 6 Fr inside biliary stent. c Novel 6 Fr inside biliary stent placement in a side-by-side manner. d Comparison of a 7 Fr inside biliary stent (left) and a 6 Fr inside biliary stent (right). Case 1: An 89-year-old man with malignant perihilar cholangiocarcinoma was admitted with acute cholangitis caused by dysfunction of a previously placed 7 Fr inside biliary stent in the left hepatic duct. After extracting the occluded biliary stent, endoscopic retrograde cholangiography (ERC) confirmed bismuth type IV perihilar biliary obstruction. The 0.025-inch guidewires were placed in the bilateral hepatic ducts. We successfully deployed 6 Fr inside biliary stents in the bile duct along the guidewire without complications ([ Fig. 2 ] a–f , [ Video 1 ]). Case 2: A 78-year-old woman with IgG4-sclerosing cholangitis was admitted to our hospital. ERC confirmed perihilar biliary obstruction. We placed 6-Fr inside biliary stents simultaneously in the bile duct ([ Fig. 3 ], [ Video 1 ]). Fig. 2 (Case 1) a A radiograph showing the left hepatic duct obstruction. b A radiograph showing a 0.025-inch guidewire placed in the right hepatic duct. ( c ) A radiograph showing the bismuth type IV biliary obstruction. d A radiograph showing the novel 6 Fr inside biliary stent inserted in the bile duct. e A radiograph showing both stents placed simultaneously in the bilateral hepatic ducts (inset: an endoscopic image). f A radiograph showing after extraction inner and pushing catheters. Download Video A novel 6 Fr inside biliary stent system for perihilar biliary drainage. The stents can be deployed simultaneously in a side-by-side fashion over the guidewire.Video 1 Fig. 3 (Case 2) a A radiograph showing the bilateral 0.025-inch guidewire placed in the right and left hepatic ducts. b A radiograph showing both stents placed simultaneously in the bilateral hepatic ducts (inset: an endoscopic image). c A radiograph showing the removal of guidewires and inner catheters. In conclusion, this novel 6 Fr inside biliary stent system is useful for treating perihilar biliary obstruction. We believe that this system is a new drainage option and the least invasive approach available for the management of BD in patients with benign and malignant perihilar biliary obstructions. Endoscopy_UCTN_Code_TTT_1AR_2AZ Publication History Article published online: 30 January 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Autor:innen und Institutionen
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan.
ORCID-Profile: Hiroshi Kawakami
Zitieren
APA
Kawakami, H., Uchiyama, N., & Hatada, H. (2026). A novel 6 Fr inside biliary stent system for perihilar biliary drainage. Endoscopy, 58(S 01 S 01), E160-E162. https://doi.org/10.1055/a-2767-1949
Vancouver
Kawakami H, Uchiyama N, Hatada H. A novel 6 Fr inside biliary stent system for perihilar biliary drainage. Endoscopy. 2026;58(S 01 S 01):E160-E162. doi:10.1055/a-2767-1949
BibTeX
@article{Kawakami2026,
author = {Kawakami, Hiroshi and Uchiyama, Naomi and Hatada, Hiroshi},
title = {A novel 6 Fr inside biliary stent system for perihilar biliary drainage},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 01 S 01},
pages = {E160--E162},
doi = {10.1055/a-2767-1949}
}
EUVIMED