Environmental footprint of gastrointestinal endoscopy services: a systematic review
Endoscopy · 01.05.2026 · 58 (05) · 529-549
DOI: 10.1055/a-2739-4080 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Endoscopy, erschienen am 01.05.2026. Verfasst von Britta Vegting und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands. Hauptthemen laut MEDLINE: Endoscopy, Gastrointestinal, Carbon Footprint. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Funded internally by Erasmus University Medical Center Convergence Sustainable Health Program..
Abstract (Originalsprache)
Gastrointestinal (GI) endoscopy is a significant contributor to health care-related climate change due to high procedure volumes, intensive decontamination processes, and reliance on single-use products. This systematic review aimed to synthesize the current evidence on the environmental impact of GI endoscopy. MEDLINE, Embase, and Web of Science were systematically searched up to May 2025 for studies assessing the environmental impact of GI endoscopy. Two reviewers independently performed study selection, data extraction, and quality assessment. The PRISMA guidelines were followed. 28 studies were included. Most studies assessed carbon emissions; only four studies (14%) examined environmental impacts beyond greenhouse gas emissions. The largest contributors to emissions were patient travel, energy use, and procedure-related products, whereas waste had limited impact. Overall, scope 3 emissions accounted for the majority of total emissions, though reporting across different emission scopes was inconsistent. In line with heterogeneity in methodology, per-procedure emissions ranged from 5.4 to 73.2 kg carbon dioxide equivalent. Overall, 21 studies (75%) were judged to have a high risk of bias. Current evidence on the environmental impact of GI endoscopy services is fragmented, methodologically inconsistent, and often limited in coverage. Emissions were dominated by patient travel, energy use, and procedure-related products. Broader and more standardized environmental assessments are needed to guide the transition to low-carbon, sustainable GI endoscopy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands.
- Department of Intensive Care, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands.
- Department of Hospital Pharmacy, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands.
- Erasmus School of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, Netherlands.
- Econometrics Institute, Erasmus School of Economics, Erasmus University Rotterdam, Rotterdam, Netherlands.
ORCID-Profile: Britta Vegting, Demi Gerritsen, Ceyda B Izci
Förderung
- Funded internally by Erasmus University Medical Center Convergence Sustainable Health Program.
Zitieren
APA
Vegting, B., Gerritsen, D., Izci, C. B., Hunfeld, N. G. M., van Raaij, E. M., van den Heuvel, W., de Jonge, P. J. F., & Siersema, P. D. (2026). Environmental footprint of gastrointestinal endoscopy services: a systematic review. Endoscopy, 58(05), 529-549. https://doi.org/10.1055/a-2739-4080
Vancouver
Vegting B, Gerritsen D, Izci CB, Hunfeld NGM, van Raaij EM, van den Heuvel W, et al. Environmental footprint of gastrointestinal endoscopy services: a systematic review. Endoscopy. 2026;58(05):529-549. doi:10.1055/a-2739-4080
BibTeX
@article{Vegting2026,
author = {Vegting, Britta and Gerritsen, Demi and Izci, Ceyda B and Hunfeld, Nicole G M and van Raaij, Erik M and van den Heuvel, Wilco and de Jonge, Pieter J F and Siersema, Peter D},
title = {Environmental footprint of gastrointestinal endoscopy services: a systematic review},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {05},
pages = {529--549},
doi = {10.1055/a-2739-4080}
}
EUVIMED