EUVIMEDEUVIMED entdecken
Vergleichsstudie

The In Vitro Biomechanics of Locking Plates Used in a Supercutaneous Fashion Compared to a Type Ia External Skeletal Fixator

Ashley Proctor, Melissa MacIver, Noel Moens, John Runciman, Scott Brandon, Gabrielle Monteith

Veterinary and Comparative Orthopaedics and Traumatology · 01.07.2026 · 39 (04) · 229-233

DOI: 10.1055/a-2738-5771 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.07.2026. Verfasst von Ashley Proctor und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies, The Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada. Hauptthemen laut MEDLINE: Bone Plates, External Fixators, Fracture Fixation, Fractures, Bone. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to determine the biomechanics of a supercutaneously placed String of Pearls plate (SOP) and supercutaneously placed locking compression plate (LCP) to be used in lieu of a type Ia external fixator. Nine surrogate constructs of 3.5 mm SOP, 3.5 mm LCP and type Ia external fixator offset 20 mm from the cortex over a 10-mm fracture gap were tested in non-destructive loading to 200 N and then tested in load to 100% displacement. Maximum displacement was used to calculate median maximum displacement in non-destructive axial compression testing for the SOP, LCP and external fixator, measuring 8.5 mm (interquartile range [IQR] 8.23–8.95), 10.3 mm (IQR 9.99–10.40) and 1.2 mm (IQR 1.17–1.31), respectively. There was a difference between the external fixator to LCP (p = 0.0050), external fixator to SOP (p = 0.0050) and LCP to SOP (p = 0.0050). Maximum load was used in compression to 100% displacement to calculate the median maximum load. The SOP, LCP and external fixator, withstood median loads to 100% displacement of 244 N (IQR 231.83–257.19), 168 N (IQR 165.07–170.86) and 766 N (IQR 688.14–784.29), respectively. There was a difference between external fixator to SOP (p = 0.0047), external fixator to LCP (p ≤ 0.001) and LCP to SOP (p = 0.0024). The type Ia external fixator is significantly stiffer compared with the supercutaneous 3.5 mm SOP and 3.5 mm LCP. Given the low stiffness and high displacement, supercutaneously placed locking plates may be unsuitable for clinical fracture repair in a 20-kg dog with an expected axial load of 200 N.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesExternal FixatorsFracture FixationFractures, BoneBiomechanical PhenomenaAnimalsMaterials Testing

Autor:innen und Institutionen

  • Department of Clinical Studies, The Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
  • School of Engineering, University of Guelph, Guelph, Ontario, Canada.

Zitieren

APA

Proctor, A., MacIver, M., Moens, N., Runciman, J., Brandon, S., & Monteith, G. (2026). The In Vitro Biomechanics of Locking Plates Used in a Supercutaneous Fashion Compared to a Type Ia External Skeletal Fixator. Veterinary and Comparative Orthopaedics and Traumatology, 39(04), 229-233. https://doi.org/10.1055/a-2738-5771

Vancouver

Proctor A, MacIver M, Moens N, Runciman J, Brandon S, Monteith G. The In Vitro Biomechanics of Locking Plates Used in a Supercutaneous Fashion Compared to a Type Ia External Skeletal Fixator. Veterinary and Comparative Orthopaedics and Traumatology. 2026;39(04):229-233. doi:10.1055/a-2738-5771

BibTeX
@article{Proctor2026,
  author = {Proctor, Ashley and MacIver, Melissa and Moens, Noel and Runciman, John and Brandon, Scott and Monteith, Gabrielle},
  title = {The In Vitro Biomechanics of Locking Plates Used in a Supercutaneous Fashion Compared to a Type Ia External Skeletal Fixator},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2026},
  volume = {39},
  number = {04},
  pages = {229--233},
  doi = {10.1055/a-2738-5771}
}
Kostenlos starten →