EUVIMEDEUVIMED entdecken
Crossref

Myocardial Perfusion SPECT 2024 in Germany: Results of the 10th Survey

Oliver Lindner, Matthias Gutberlet, Wolfgang Burchert, Thorsten Derlin, Christoph Rischpler

Nuklearmedizin - NuclearMedicine · 01.02.2026 · 65 (01) · 30-38

DOI: 10.1055/a-2738-2589 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.02.2026. Verfasst von Oliver Lindner und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiology, Nuclearmedicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, Bad Oeynhausen, Germany. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Tomography, Emission-Computed, Single-Photon. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the results of the 10th survey of myocardial perfusion SPECT (MPS) from the year 2024. A total of 198 questionnaires were evaluated, comprising 115 practices (PR), 57 hospitals (HO) and 26 university hospitals (UH). The results of the previous survey 2021 are shown in squared brackets. MPS data from 128.707 [133.057] patients (–3.3%) with 125.175 [131.868] stress and 102.903 [106.546] rest MPS were analysed. A comparison with official data revealed that 53% of all MPS were recorded. From 2018 to 2024, official data showed an increase in MPS every year. In 2024, on average, 650 [610] MPS patients (+7%) were examined in each department. Of the participating departments, 69% [74%] reported an increase or no changes in their patient numbers. As always ambulatory care cardiologists represented the major referral group (68% [69%]). Pharmacological stress was performed more frequently than ergometry (43% [42%]). Regadenoson was mostly used. The use of the different protocols remained almost unchanged. Two-day protocols were predominantly applied (49% [49%]). Multi-head cameras were used in (56% [58%] of the departments and SPECT-CT systems in (31% [28%]). Attenuation correction was performed in 35% [33%] of all MPS. 95% [89%] of all stress, 93% [88%] of all rest and 92% [87%] of all stress and rest scan were acquired as gated SPECT. 84% [72%] of the departments performed scoring by default. The proportion of departments not scoring decreased to 4% [13%]. The MPS 2024 survey indicates that the long-term positive development of MPS imaging is continuing. The procedural and technical details of MPS imaging demonstrate a high level of conformity with guidelines, with a slight improvement observed from 2021 to 2024.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial Perfusion ImagingTomography, Emission-Computed, Single-PhotonHumansGermanySurveys and QuestionnairesMaleFemale

Autor:innen und Institutionen

  • Institute of Radiology, Nuclearmedicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, Bad Oeynhausen, Germany.
  • Department of Radiology, Leipzig Heart Centre University Hospital, Leipzig, Germany.
  • Clinic for Nuclear Medicine, City of Stuttgart Hospitals Katharinenhospital, Stuttgart, Germany.

Zitieren

APA

Lindner, O., Gutberlet, M., Burchert, W., Derlin, T., & Rischpler, C. (2026). Myocardial Perfusion SPECT 2024 in Germany: Results of the 10th Survey. Nuklearmedizin - NuclearMedicine, 65(01), 30-38. https://doi.org/10.1055/a-2738-2589

Vancouver

Lindner O, Gutberlet M, Burchert W, Derlin T, Rischpler C. Myocardial Perfusion SPECT 2024 in Germany: Results of the 10th Survey. Nuklearmedizin - NuclearMedicine. 2026;65(01):30-38. doi:10.1055/a-2738-2589

BibTeX
@article{Lindner2026,
  author = {Lindner, Oliver and Gutberlet, Matthias and Burchert, Wolfgang and Derlin, Thorsten and Rischpler, Christoph},
  title = {Myocardial Perfusion SPECT 2024 in Germany: Results of the 10th Survey},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2026},
  volume = {65},
  number = {01},
  pages = {30--38},
  doi = {10.1055/a-2738-2589}
}