Newly developed plastic stent delivery system for endoscopic ultrasonography-guided gallbladder drainage: Experiments on gallbladder models
Endoscopy International Open · 11.11.2025 · 13 (CP)
DOI: 10.1055/a-2734-0383 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 11.11.2025. Verfasst von Tesshin Ban und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Gamagori City Hospital, Gamagori, Japan. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Endoscopic ultrasonography-guided gallbladder drainage (EUS-GBD) using the current plastic stent (PS) system requires multiple steps for stent deployment and carries the risk of bile leakage from the puncture site. In this study, we developed a single-step PS system that includes a 3F electrocautery metal tip on the inner sheath mounted with a 7F/4-cm double-pigtail PS and experimentally evaluated it on a gallbladder model mimicking EUS-GBD. We assessed procedure time, intra-gallbladder pressure-drop ratios, and bile leakage using a newly developed single-step PS system, comparing it with the current PS system during drainage attempts on a gallbladder model. Mean duration times for the three attempts were 2 minutes 59 seconds and 27 seconds for the current PS system and the newly developed PS system groups, respectively (P < 0.001). Mean intra-gallbladder pressure-drop ratios were 86.7% in the current PS system group and 7.6% in the newly developed PS system group (P < 0.001). The newly developed PS system prevented bile leakage from the puncture site. The newly developed PS system saved significant time, maintained intra-gallbladder pressure, and prevented bile leakage during the procedure when compared with the current PS system.
Autor:innen und Institutionen
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Gamagori, Japan.
ORCID-Profile: Tesshin Ban
Zitieren
APA
Ban, T., Kubota, Y., & Joh, T. (2025). Newly developed plastic stent delivery system for endoscopic ultrasonography-guided gallbladder drainage: Experiments on gallbladder models. Endoscopy International Open, 13(CP). https://doi.org/10.1055/a-2734-0383
Vancouver
Ban T, Kubota Y, Joh T. Newly developed plastic stent delivery system for endoscopic ultrasonography-guided gallbladder drainage: Experiments on gallbladder models. Endoscopy International Open. 2025;13(CP). doi:10.1055/a-2734-0383
BibTeX
@article{Ban2025,
author = {Ban, Tesshin and Kubota, Yoshimasa and Joh, Takashi},
title = {Newly developed plastic stent delivery system for endoscopic ultrasonography-guided gallbladder drainage: Experiments on gallbladder models},
journal = {Endoscopy International Open},
year = {2025},
volume = {13},
number = {CP},
doi = {10.1055/a-2734-0383}
}
EUVIMED