Abstract (Originalsprache)
This meta-analysis aimed to evaluate the long-term outcomes of a low-intensity anticoagulation (LA) strategy in patients undergoing mechanical aortic valve replacement. A systematic search of the databases was conducted through October 2024. Single-arm meta-analysis was performed to estimate the pooled late outcomes associated with LA. The Kaplan–Meier survival curve was reconstructed using individual patient data from included studies to assess overall survival. A standard meta-analysis was then conducted to compare outcomes between LA and standard anticoagulation (SA). Eight studies, comprising 2,426 patients and 21,062.7 patient-years, were included. Five studies involved comparable groups, while three were single-arm studies. The pooled valve-related mortality rate with LA was 0.05 per 100 patient-year, with incidences of prosthetic valve thrombosis, composite of bleeding and thromboembolism, bleeding, and thromboembolism being 0.03, 1.5, 0.93, and 0.46 per 100 patient-year, respectively. The Kaplan–Meier analysis showed overall survival rates at 10 years of 88.5%. Compared with SA, LA was associated with significantly lower risks of all-cause mortality (hazard ratio [HR]: 0.50; 95% confidence interval [CI]: 0.37–0.68; p < 0.01), composite outcome (HR: 0.49; 95% CI: 0.37–0.66; p < 0.01), and bleeding (HR: 0.37; 95% CI: 0.26–0.52; p < 0.01). There were no significant differences in valve thrombosis (HR: 0.52; 95% CI: 0.13–2.11; p = 0.36) or thromboembolic event rates (HR: 0.88; 95% CI: 0.50–1.54; p = 0.65). This meta-analysis suggests that LA is associated with reduced risks of all-cause mortality and bleeding compared with SA, while thromboembolic risks remain comparable.
Zitieren
APA
Naito, N., & Takagi, H. (2025). Meta-Analysis of Low-Intensity versus Standard Anticoagulation for Mechanical Aortic Valves. International Journal of Angiology. https://doi.org/10.1055/a-2733-0889
Vancouver
Naito N, Takagi H. Meta-Analysis of Low-Intensity versus Standard Anticoagulation for Mechanical Aortic Valves. International Journal of Angiology. 2025. doi:10.1055/a-2733-0889
BibTeX
@article{Naito2025,
author = {Naito, Noritsugu and Takagi, Hisato},
title = {Meta-Analysis of Low-Intensity versus Standard Anticoagulation for Mechanical Aortic Valves},
journal = {International Journal of Angiology},
year = {2025},
doi = {10.1055/a-2733-0889}
}
EUVIMED