Clinical and environmental implications of a high-density clip closure after endoscopic submucosal dissection: is it worth it?
Endoscopy · 01.12.2025 · 57 (S 01 S 01) · E1173-E1174
DOI: 10.1055/a-2717-1584 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2025. Verfasst von Elena De Cristofaro und 6 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Prophylactic clip closure for the prevention of delayed bleeding after endoscopic submucosal dissection (ESD) remains debated. While some retrospective studies have shown a benefit, recent randomized trials have not confirmed it [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ]. These studies often report the use of many clips to achieve closure, emphasizing tight, high-density placement. However, this practice is not standardized, and such variability raises additional concerns regarding procedural costs and environmental impact. In our clinical practice, closure is considered complete when no visible mucosal defect remains after clip placement ([ Fig. 1 ]). Fig. 1 Two different techniques for closing a mucosal defect after endoscopic submucosal dissection. Panel a : Complete closure with standard clip placement and without any visible residual mucosal defect. Panel b : Complete closure with high-density clip placement. Here, we present the case of a 76-year-old man referred for endoscopic resection of a large (7 cm), non-granular laterally spreading tumor at the hepatic flexure. Due to the lesion’s characteristics, ESD was indicated and successfully performed using an adaptive traction device (A-TRACT) in 70 minutes. The Limoges bleeding risk score was 5 points, indicating high risk. Therefore, complete prophylactic clip closure was performed. Closure was performed using the clip-anchoring technique, with incisions enhancing a clip grip. Departing from our standard practice, we applied a “Japanese-style” closure with
Autor:innen und Institutionen
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy.
- Gastroenterology and Endoscopy Unit, Edouard Herriot Hospital, Hospices Civils de Lyon, Lyon, France.
- Gastroenterology and Endoscopy Unit, Dupuytren University Hospital, Limoges, France.
- Gastroenterology and Endoscopy Unit, Pontchaillou University Hospital, Rennes, France.
ORCID-Profile: Elena De Cristofaro, Jean Grimaldi
Zitieren
APA
De Cristofaro, E., Grimaldi, J., Jacques, J., Rivory, J., Troncone, E., Wallenhorst, T., & Pioche, M. (2025). Clinical and environmental implications of a high-density clip closure after endoscopic submucosal dissection: is it worth it?. Endoscopy, 57(S 01 S 01), E1173-E1174. https://doi.org/10.1055/a-2717-1584
Vancouver
De Cristofaro E, Grimaldi J, Jacques J, Rivory J, Troncone E, Wallenhorst T, et al. Clinical and environmental implications of a high-density clip closure after endoscopic submucosal dissection: is it worth it?. Endoscopy. 2025;57(S 01 S 01):E1173-E1174. doi:10.1055/a-2717-1584
BibTeX
@article{DeCristofaro2025,
author = {De Cristofaro, Elena and Grimaldi, Jean and Jacques, Jérémie and Rivory, Jérôme and Troncone, Edoardo and Wallenhorst, Timothée and Pioche, Mathieu},
title = {Clinical and environmental implications of a high-density clip closure after endoscopic submucosal dissection: is it worth it?},
journal = {Endoscopy},
year = {2025},
volume = {57},
number = {S 01 S 01},
pages = {E1173--E1174},
doi = {10.1055/a-2717-1584}
}