EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Half Burr-Hole Method: A Novel Surgical Technique for Reducing Brain Shift and Improving Electrode Placement Accuracy in Deep-Brain Stimulation

Yosuke Ito, Masafumi Fukuda, Tomoyoshi Ota, Hiroshi Masuda, Makoto Oishi

Journal of Neurological Surgery Reports · 01.10.2025 · 86 (04) · e189-e193

DOI: 10.1055/a-2707-0593 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Neurological Surgery Reports, erschienen am 01.10.2025. Verfasst von Yosuke Ito und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Nishi Niigata Chuo National Hospital, Niigata, Japan. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Deep-brain stimulation (DBS) is used to treat movement disorders and drug-resistant focal epilepsy. However, electrode placement accuracy is affected by brain shift caused by pneumocephalus and cerebrospinal fluid (CSF) leakage during surgery. We present the novel half burr-hole method for improved DBS electrode placement accuracy. This approach was used to treat a 28-year-old man with drug-resistant epilepsy in whom stereo-electroencephalography revealed bilateral seizure onset in the temporal lobes, precluding focal resection. The patient, under general anesthesia, was placed in the supine position. Using a ROSA robot-assisted surgical system, approximately 8-mm-deep “partial burr-holes” were created, with the deeper portion perforated using a 2.4-mm twist drill. Stimulation electrodes were placed bilaterally in the anterior thalamic nucleus. Directional leads were secured using standard burr-hole caps. Postoperative computed tomography confirmed a 0.46-cm3 pneumocephalus and electrode positioning with 0.47 mm (range: 0–1.62 mm) vector and 0.12 mm (range: 0.08–0.16 mm) axial errors relative to the target coordinates. Postoperative electrode impedance values were within the normal range. The half burr-hole method effectively minimizes CSF leakage and pneumocephalus during DBS surgery, reducing brain shift and enhancing electrode placement accuracy, and is compatible with standard burr-hole caps for electrode fixation, minimally affecting impedance values.

Schlagwörter

Stichwörter der Autor:innen

anterior thalamic nucleusdeep-brain stimulationpneumocephalus

Autor:innen und Institutionen

  • Department of Neurosurgery, Nishi Niigata Chuo National Hospital, Niigata, Japan.
  • Department of Neurosurgery, Niigata University Brain Research Institute Clinical Neuroscience Branch, Niigata, Japan.

Zitieren

APA

Ito, Y., Fukuda, M., Ota, T., Masuda, H., & Oishi, M. (2025). Half Burr-Hole Method: A Novel Surgical Technique for Reducing Brain Shift and Improving Electrode Placement Accuracy in Deep-Brain Stimulation. Journal of Neurological Surgery Reports, 86(04), e189-e193. https://doi.org/10.1055/a-2707-0593

Vancouver

Ito Y, Fukuda M, Ota T, Masuda H, Oishi M. Half Burr-Hole Method: A Novel Surgical Technique for Reducing Brain Shift and Improving Electrode Placement Accuracy in Deep-Brain Stimulation. Journal of Neurological Surgery Reports. 2025;86(04):e189-e193. doi:10.1055/a-2707-0593

BibTeX
@article{Ito2025,
  author = {Ito, Yosuke and Fukuda, Masafumi and Ota, Tomoyoshi and Masuda, Hiroshi and Oishi, Makoto},
  title = {Half Burr-Hole Method: A Novel Surgical Technique for Reducing Brain Shift and Improving Electrode Placement Accuracy in Deep-Brain Stimulation},
  journal = {Journal of Neurological Surgery Reports},
  year = {2025},
  volume = {86},
  number = {04},
  pages = {e189--e193},
  doi = {10.1055/a-2707-0593}
}
Kostenlos starten →