EUVIMEDEUVIMED entdecken
Vergleichsstudie

Differential Perfusion Patterns of Perforator and Random Flaps Assessed by Indocyanine Green Imaging

Abdullh Z AlQhtani iD, Nara Lee, Hyungbae Kim, Jin Sup Eom, Hyun Ho Han iD

Journal of Reconstructive Microsurgery · 01.09.2026 · 42 (07) · 548-553

DOI: 10.1055/a-2702-4290 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.09.2026. Verfasst von Abdullh Z AlQhtani und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic Surgery, Surgery, College of Medicine, Prince Sattam Bin Abdulaziz University, Al Kharj, Saudi Arabia. Hauptthemen laut MEDLINE: Indocyanine Green, Perforator Flap, Surgical Flaps. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Indocyanine green angiography (ICGA) is widely used to evaluate flap perfusion in reconstructive surgery, but the optimal timing for assessment may differ by flap type. This study compared the perfusion dynamics of perforator and random pattern flaps in a rat model using ICGA. ICGA dynamics were compared between perforator and random flaps in a rat model. Sixteen Sprague–Dawley rats (275–300 g) were randomly assigned to either a perforator or a random flap group. A 0.25-mg dose of indocyanine green (ICG) was administered via the femoral vein, and fluorescence images were acquired at predefined intervals over 4 minutes. Hypoperfusion was defined as fluorescence intensity below 30% of the peak value. Necrosis was assessed on postoperative day 7. Statistical analyses included the Mann–Whitney U and log-rank tests with Expectation-Maximization Iterative Convex Minorant (EMICM) modeling. In the perforator flap group, the final area of necrosis corresponded to the ICGA-defined perfusion boundary observed between 10 and 50 seconds postinjection. In contrast, necrosis in the random flap group aligned with the ICGA-defined perfusion boundary captured between 30 and 150 seconds. The most accurate time points for necrosis prediction were 50 seconds for perforator flaps and 150 seconds for random flaps, both demonstrating statistical significance (p = 0.0028). ICGA timing requirements differ between flap types. Implementing flap-specific assessment windows may enhance intraoperative interpretation and reduce false-positive findings. These findings support the development of flap-specific ICGA protocols to improve intraoperative decision-making in reconstructive surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Indocyanine GreenPerforator FlapSurgical FlapsAnimalsRats, Sprague-DawleyRatsNecrosisColoring AgentsRandom AllocationAngiographyMale

Substanzen

Indocyanine GreenColoring Agents

Autor:innen und Institutionen

  • Department of Plastic Surgery, Surgery, College of Medicine, Prince Sattam Bin Abdulaziz University, Al Kharj, Saudi Arabia.
  • Department of Plastic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.

ORCID-Profile: Abdullh Z AlQhtani, Hyun Ho Han

Zitieren

APA

AlQhtani, A. Z., Lee, N., Kim, H., Eom, J. S., & Han, H. H. (2026). Differential Perfusion Patterns of Perforator and Random Flaps Assessed by Indocyanine Green Imaging. Journal of Reconstructive Microsurgery, 42(07), 548-553. https://doi.org/10.1055/a-2702-4290

Vancouver

AlQhtani AZ, Lee N, Kim H, Eom JS, Han HH. Differential Perfusion Patterns of Perforator and Random Flaps Assessed by Indocyanine Green Imaging. Journal of Reconstructive Microsurgery. 2026;42(07):548-553. doi:10.1055/a-2702-4290

BibTeX
@article{AlQhtani2026,
  author = {AlQhtani, Abdullh Z and Lee, Nara and Kim, Hyungbae and Eom, Jin Sup and Han, Hyun Ho},
  title = {Differential Perfusion Patterns of Perforator and Random Flaps Assessed by Indocyanine Green Imaging},
  journal = {Journal of Reconstructive Microsurgery},
  year = {2026},
  volume = {42},
  number = {07},
  pages = {548--553},
  doi = {10.1055/a-2702-4290}
}
Kostenlos starten →