EUVIMEDEUVIMED entdecken
Crossref

Ultrasound findings in 46 cases of incomplete release of the transverse carpal ligament in carpal tunnel surgery

Marco Becciolini iD, Giorgio Tamborrini, Christopher Pivec, Georg Riegler

Ultraschall in der Medizin - European Journal of Ultrasound · 01.06.2026 · 47 (03) · 284-293

DOI: 10.1055/a-2672-2835 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultraschall in der Medizin - European Journal of Ultrasound, erschienen am 01.06.2026. Verfasst von Marco Becciolini und 3 weiteren Autor:innen. Beteiligte Einrichtung: Misericordia di Pistoia, Ultrasound, Italy, Pistoia. Hauptthemen laut MEDLINE: Carpal Tunnel Syndrome, Postoperative Complications, Ligaments, Articular. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To describe the ultrasound (US) features of a complication in patients who have undergone surgery for carpal tunnel syndrome (CTS): the incomplete release of the transverse carpal ligament (TCL). Reports from two institutions were searched using the keywords “persistent CTS” and “incomplete TCL release”. Post-surgical US examinations were performed using a standardized approach at both institutions, first assessing the muscles supplied by the median nerve (MN) and then conducting a detailed evaluation of the MN course at the wrist. To avoid misinterpreting ligament regrowth, patients with recurrent symptoms two months or later after surgery were excluded. Only cases showing clear compression by the TCL were selected. A total of 46 patients were identified with incomplete release of the TCL, with the average uncut portion of the ligament measuring 6.7 mm. The proximal margin of the TCL was incompletely released in 65% of the cases, while the distal margin was affected in 35%. Symptoms in these patients persisted after surgery, and, in 52%, they were worse than before surgery. A reduction in thenar muscle bulk was observed in 37 patients. Follow-up clinical data were available in eight patients, with three undergoing US evaluation after revision surgery. US can effectively demonstrate the incomplete release of the TCL, visualized as a fibrillar uncut structure compressing the MN and producing an hourglass appearance of the nerve. In addition, US may help detect other factors that contribute to persistent symptoms and help to guide revision surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carpal Tunnel SyndromePostoperative ComplicationsLigaments, ArticularHumansFemaleUltrasonographyMaleMiddle AgedAdultAgedMedian NerveReoperationDecompression, SurgicalFollow-Up Studies

Autor:innen und Institutionen

  • Misericordia di Pistoia, Ultrasound, Italy, Pistoia.
  • Scuola Siumb di Ecografia Muscolo-Scheletrica, Ultrasound, Italy, Pisa.
  • Swiss Ultrasound Center, Institute of Rheumatology, Switzerland, Basel.
  • PUC - Private Ultrasound Center Vienna, Ultrasound, Austria, Vienna.
  • PUC - Private Ultrasound Center Graz, Ultrasound, Austria, Graz.

ORCID-Profile: Marco Becciolini

Zitieren

APA

Becciolini, M., Tamborrini, G., Pivec, C., & Riegler, G. (2026). Ultrasound findings in 46 cases of incomplete release of the transverse carpal ligament in carpal tunnel surgery. Ultraschall in der Medizin - European Journal of Ultrasound, 47(03), 284-293. https://doi.org/10.1055/a-2672-2835

Vancouver

Becciolini M, Tamborrini G, Pivec C, Riegler G. Ultrasound findings in 46 cases of incomplete release of the transverse carpal ligament in carpal tunnel surgery. Ultraschall in der Medizin - European Journal of Ultrasound. 2026;47(03):284-293. doi:10.1055/a-2672-2835

BibTeX
@article{Becciolini2026,
  author = {Becciolini, Marco and Tamborrini, Giorgio and Pivec, Christopher and Riegler, Georg},
  title = {Ultrasound findings in 46 cases of incomplete release of the transverse carpal ligament in carpal tunnel surgery},
  journal = {Ultraschall in der Medizin - European Journal of Ultrasound},
  year = {2026},
  volume = {47},
  number = {03},
  pages = {284--293},
  doi = {10.1055/a-2672-2835}
}
Kostenlos starten →