EUVIMEDEUVIMED entdecken
Crossref

Is a functional capacity evaluation associated with a more realistic appraisal of patients’ self-reported functional capacity? A diagnostic before-after study

Martin Schindl iD, Harald T Zipko, Matthias Bethge

Die Rehabilitation · 01.12.2025 · 64 (06) · 344-350

DOI: 10.1055/a-2654-5933 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Die Rehabilitation, erschienen am 01.12.2025. Verfasst von Martin Schindl und 2 weiteren Autor:innen. Beteiligte Einrichtung: Phys. Medicine, Rehab Center "Weisser Hof", AUVA, Klosterneuburg, Austria. Hauptthemen laut MEDLINE: Self Report, Disability Evaluation, Activities of Daily Living. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Our study analyzed whether self-reported functional capacity is more realistic after a functional capacity evaluation has been carried out, i. e. whether the second self-reported functional capacity after testing corresponds more closely to the tester-observed judgement during the test than the first self-reported functional capacity before testing. Patients with orthopedic trauma were referred for functional capacity evaluation at the end of an inpatient rehabilitation program in Austria and were consecutively recruited for a diagnostic before–after study. We assessed self-reported functional capacity before and after completion of functional capacity evaluation as patient-reported outcome and compared it with tester-observed functional capacity when performing the functional capacity evaluation, i. e. our diagnostic procedure. Self-reported functional capacity was assessed with the Spinal Function Sort. In 523 patients, self-reported functional capacity assessed by the Spinal Function Sort increased significantly by 15.4 points after the functional capacity evaluation. This change corresponded to slightly more than 40% of the baseline standard deviation. The frequencies of self-reported moderate and heavy or very heavy work functional capacity increased from 22.2% to 30.4% and 13.6% to 23.5%, respectively, while the frequency of self-reported sedentary functional capacity decreased from 35.2% to 18.9%. The number of patients whose self-reported functional capacity matched the tester-observed functional capacity increased from 19.3% to 34.2% after completion of the functional capacity evaluation. After completion of the functional capacity evaluation, the number of patients significantly increased whose rating of functional capacity matched their tester-observed functional capacity

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Self ReportDisability EvaluationActivities of Daily LivingHumansMaleFemaleAustriaMiddle AgedAdultAgedReproducibility of ResultsPatient Reported Outcome Measures

Autor:innen und Institutionen

  • Phys. Medicine, Rehab Center "Weisser Hof", AUVA, Klosterneuburg, Austria.
  • Department for Health Sciences, University of Applied Sciences, Vienna, Austria.
  • Institute of Epidemiology and Social Medicine, University of Lübeck, Lübeck, Germany.

ORCID-Profile: Martin Schindl

Zitieren

APA

Schindl, M., Zipko, H. T., & Bethge, M. (2025). Is a functional capacity evaluation associated with a more realistic appraisal of patients’ self-reported functional capacity? A diagnostic before-after study. Die Rehabilitation, 64(06), 344-350. https://doi.org/10.1055/a-2654-5933

Vancouver

Schindl M, Zipko HT, Bethge M. Is a functional capacity evaluation associated with a more realistic appraisal of patients’ self-reported functional capacity? A diagnostic before-after study. Die Rehabilitation. 2025;64(06):344-350. doi:10.1055/a-2654-5933

BibTeX
@article{Schindl2025,
  author = {Schindl, Martin and Zipko, Harald T and Bethge, Matthias},
  title = {Is a functional capacity evaluation associated with a more realistic appraisal of patients’ self-reported functional capacity? A diagnostic before-after study},
  journal = {Die Rehabilitation},
  year = {2025},
  volume = {64},
  number = {06},
  pages = {344--350},
  doi = {10.1055/a-2654-5933}
}
Kostenlos starten →