EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Endoscopic ultrasound-guided hepaticogastrostomy in a patient with complex postsurgical anatomy after subtotal esophagectomy

Kei Yane iD, Keita Seto, Koki Yoshida, Sota Hirokawa, Kotaro Morita, Yuki Ikeda, Tetsuya Sumiyoshi iD

Endoscopy · 01.12.2025 · 57 (S 01 S 01) · E819-E820

DOI: 10.1055/a-2646-1668 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2025. Verfasst von Kei Yane und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Tonan Hospital, Sapporo, Japan. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In patients with complex upper gastrointestinal reconstruction, endoscopic biliary drainage is technically challenging. Recently, the usefulness of endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) in patients with surgically altered anatomy has been increasingly demonstrated [ 1 ] [ 2 ] [ 3 ] [ 4 ]. A 75-year-old man with a history of distal gastrectomy with Billroth I reconstruction for a duodenal ulcer and subtotal esophagectomy for esophagogastric junction cancer presented with a recurrent tumor and obstructive jaundice. Esophageal reconstruction was performed using a free jejunal interposition graft via the presternal route. Computed tomography revealed a duodenal obstruction from the tumor recurrence, precluding transpapillary biliary drainage ([ Fig. 1 ]). Therefore, EUS-HGS was planned to achieve internal biliary drainage. Fig. 1 Computed tomography showing intrahepatic bile duct dilation and duodenal obstruction because of the recurrent tumor (arrows). a Axial image. b Coronal image. A long colonoscope was used to navigate the interposed jejunal limb, allowing guidewire placement in the stomach. The colonoscope was then exchanged for a curved linear echoendoscope (EG-740UT; Fujifilm, Tokyo, Japan), and the guidewire was followed under fluoroscopic guidance to reach the stomach ([ Video 1 ]). From a reversed position in the upper gastric body, a dilated intrahepatic bile duct (B2) was identified ([ Fig. 2 ]). The puncture was performed using a 22-G fine-needle aspiration needle (Expect Slimline; Boston Scientific, Marlborough, Massachusetts, USA), and a 0.018-inch guidewire (Fielder 18; Olympus, Tokyo, Japan) was advanced. The tract was dilated using a double-lumen dilator (MEISSA; Japan Lifeline, Tokyo, Japan) and a 4-mm balloon catheter (REN; Kaneka Medics, Osaka, Japan) ([ Fig. 3 ]). An 8 × 120-mm covered self-expandable metal stent (Niti-S Biliary S-type; Taewoong Medical, Gyeonggi-do, South Korea) was deployed ([ Fig. 4 ]). Fig. 2 a A curved linear echoendoscope was advanced into the stomach following the guidewire under fluoroscopic guidance. b From a reversed position in the upper gastric body, a dilated intrahepatic bile duct (B2) was identified. Fig. 3 a Puncture was performed using a 22-G fine-needle aspiration needle, and a 0.018-inch guidewire was advanced. b The tract was dilated using a 4-mm balloon catheter. Fig. 4 An 8 × 120-mm covered self-expandable metal stent was deployed. Download Video Endoscopic ultrasound-guided hepaticogastrostomy in a patient with esophageal reconstruction using a free jejunal interposition graft via the presternal route.Video 1 The total procedure time was 58 minutes. There were no adverse events postoperatively, and jaundice resolved promptly. Stent dysfunction was not observed until the patient’s death from the primary disease. EUS-HGS is a promising option for biliary drainage in patients with a malignant obstruction and complex surgical anatomy. Thorough preprocedural planning, including an understanding of the surgically altered anatomy and appropriate device selection, is essential for procedural success. Endoscopy_UCTN_Code_TTT_1AS_2AH Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 25 July 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Autor:innen und Institutionen

  • Department of Gastroenterology, Tonan Hospital, Sapporo, Japan.

ORCID-Profile: Kei Yane, Tetsuya Sumiyoshi

Zitieren

APA

Yane, K., Seto, K., Yoshida, K., Hirokawa, S., Morita, K., Ikeda, Y., & Sumiyoshi, T. (2025). Endoscopic ultrasound-guided hepaticogastrostomy in a patient with complex postsurgical anatomy after subtotal esophagectomy. Endoscopy, 57(S 01 S 01), E819-E820. https://doi.org/10.1055/a-2646-1668

Vancouver

Yane K, Seto K, Yoshida K, Hirokawa S, Morita K, Ikeda Y, et al. Endoscopic ultrasound-guided hepaticogastrostomy in a patient with complex postsurgical anatomy after subtotal esophagectomy. Endoscopy. 2025;57(S 01 S 01):E819-E820. doi:10.1055/a-2646-1668

BibTeX
@article{Yane2025,
  author = {Yane, Kei and Seto, Keita and Yoshida, Koki and Hirokawa, Sota and Morita, Kotaro and Ikeda, Yuki and Sumiyoshi, Tetsuya},
  title = {Endoscopic ultrasound-guided hepaticogastrostomy in a patient with complex postsurgical anatomy after subtotal esophagectomy},
  journal = {Endoscopy},
  year = {2025},
  volume = {57},
  number = {S 01 S 01},
  pages = {E819--E820},
  doi = {10.1055/a-2646-1668}
}