EUVIMEDEUVIMED entdecken
Multizentrische StudieRandomisierte kontrollierte Studie

A novel artificial intelligence-based system for quality monitoring during esophagogastroduodenoscopy: a multicenter randomized controlled study

Ein neuartiges KI-basiertes System zur Qualitätsüberwachung während der Ösophagogastroduodenoskopie: multizentrische randomisierte kontrollierte Studie

Shengsen Chen, Yandong Li, Huogen Wang, Ming Chen, Chun Wang, Weilong Pan, Ji Ma, Tingting Ji, Jiemin Hong, Di Hu, Xiancang Sheng, Junbing Jiang und 1 weitere

Endoscopy · 2025-11 · 57 (11) · 1185-1194

DOI: 10.1055/a-2626-0069 ↗

Auf einen Blick

Bei 16 005 Kontrollen und 16 012 mit EQCA war die Detektionsrate für UGI-Krebs-assoziierte Läsionen und Krebs höher als unter Kontrolle.

Fragestellung

Verbessert das EQCA-Assistenzsystem bei der Ösophagogastroduodenoskopie die Detektion von UGI-Krebs-assoziierten Läsionen und Krebs?

Methode

Multizentrische randomisierte kontrollierte Studie in sieben Krankenhäusern; Patient:innen ab 18 Jahren wurden konsekutiv eingeschlossen und EQCA oder Kontrolle zugeteilt.

Ergebnisse

Nach Randomisierung und Ausschlüssen wurden 16 005 in der Kontrollgruppe und 16 012 in der EQCA-Gruppe analysiert. Detektion UGI-Krebs-assoziierter Läsionen: 8.00 % vs. 5.55 %; Krebs: 1.93 % vs. 1.21 %; beide P < 0.001.

Schlussfolgerung der Autor:innen

Der Einsatz von EQCA während der EGD war mit einer erhöhten Detektion von UGI-Krebs und präkanzerösen Läsionen verbunden. Das System kann ein wirksames Tool zur Echtzeit-Qualitätsüberwachung sein.

Kernaussagen

  • Detektion UGI-Krebs-assoziierter Läsionen: 8.00 % vs. 5.55 %
  • Detektion von UGI-Krebs: 1.93 % vs. 1.21 %
  • EQCA war mit höherem Operation Score und längerer Inspektionszeit verbunden

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Multizentrische Studie in der Zeitschrift Endoscopy, online erschienen am 01.07.2025. Verfasst von Shengsen Chen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endoscopy, Zhejiang Cancer Hospital, Hangzhou, China. Hauptthemen laut MEDLINE: Artificial Intelligence, Endoscopy, Digestive System. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: Zhejiang Traditional Chinese Medicine Administration, Natural Science Foundation for Young Scientists, Natural Science Foundation of Zhejiang Province.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Esophagogastroduodenoscopy (EGD) is the pivotal procedure for diagnosis of upper gastrointestinal (UGI) lesions. However, significant variation in EGD performance among endoscopists impacts detection rates of UGI cancers and precursor lesions. We developed a novel EGD quality monitoring system and evaluated its effectiveness in a randomized controlled study. The endoscopy quality control assistant (EQCA) was developed using deep convolutional neural networks and long short-term memory. Patients (≥18 years) undergoing EGD in seven hospitals were consecutively enrolled and randomly assigned to the EQCA-assisted group or control group. The primary outcome was the detection rate for cancer-related lesions (low and high grade intraepithelial neoplasia and cancer) and cancer (early and advanced cancer) in the UGI tract. After randomization and exclusions, 16 005 patients in the control group and 16 012 in the EQCA group were analyzed. Detection rates for UGI cancer-related lesions and cancer were significantly higher in the EQCA group than in the control group (8.00% vs. 5.55%; 1.93% vs. 1.21%; both P < 0.001). The EQCA group had a higher operation score, reflecting examination quality, and longer inspection time than the control group. The detection rate for UGI cancer-related lesions was positively correlated with operation score (r = 0.9217, P < 0.001) and inspection time (r = 0.8943, P < 0.001) for each hospital. The use of EQCA during EGD was associated with increased detection of UGI cancer and precancerous lesions. Our novel EQCA system can be an effective tool for monitoring real-time EGD quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceEndoscopy, Digestive SystemAgedFemaleHumansMaleMiddle AgedQuality Control

Autor:innen und Institutionen

  • Department of Endoscopy, Zhejiang Cancer Hospital, Hangzhou, China.
  • Graduate Student Training Base Alliance, Wenzhou Medical University, Wenzhou, China.
  • Hithink RoyalFlush Information Network Co. Ltd., Hangzhou, China.
  • Department of Gastroenterology, Xinchang People's Hospital, Shaoxing, China.
  • Department of Gastroenterology, The First People's Hospital of Yongkang, Jinhua, China.
  • Department of Gastroenterology, Ruian People's Hospital, Wenzhou, China.

ORCID-Profile: Shi Wang

Förderung

  • Zhejiang Traditional Chinese Medicine Administration
  • Natural Science Foundation for Young Scientists
  • Natural Science Foundation of Zhejiang Province
  • Medical and Health Research Project of Zhejiang Province

Zitieren

APA

Chen, S., Li, Y., Wang, H., Chen, M., Wang, C., Pan, W., Ma, J., Ji, T., Hong, J., Hu, D., Sheng, X., Jiang, J., & Wang, S. (2025). A novel artificial intelligence-based system for quality monitoring during esophagogastroduodenoscopy: a multicenter randomized controlled study. Endoscopy, 57(11), 1185-1194. https://doi.org/10.1055/a-2626-0069

Vancouver

Chen S, Li Y, Wang H, Chen M, Wang C, Pan W, et al. A novel artificial intelligence-based system for quality monitoring during esophagogastroduodenoscopy: a multicenter randomized controlled study. Endoscopy. 2025;57(11):1185-1194. doi:10.1055/a-2626-0069

BibTeX
@article{Chen2025,
  author = {Chen, Shengsen and Li, Yandong and Wang, Huogen and Chen, Ming and Wang, Chun and Pan, Weilong and Ma, Ji and Ji, Tingting and Hong, Jiemin and Hu, Di and Sheng, Xiancang and Jiang, Junbing and Wang, Shi},
  title = {A novel artificial intelligence-based system for quality monitoring during esophagogastroduodenoscopy: a multicenter randomized controlled study},
  journal = {Endoscopy},
  year = {2025},
  volume = {57},
  number = {11},
  pages = {1185--1194},
  doi = {10.1055/a-2626-0069}
}
Kostenlos starten →