EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the accuracy of magnetic resonance imaging in identifying early rectal cancers suitable for endoscopic intermuscular dissection

Lisa van der Schee iD, Rachel Carten, Sander C Albers, Janneke van den Bergh, Manon N G J A Braat, Arnold C Goede, Sabrine Kol, Miangela M Lacle, Banafsche Mearadji, Shira I Moos, Irene M Nota, Nicky H G M Peters und 10 weitere

Endoscopy · 01.12.2025 · 57 (12) · 1376-1385

DOI: 10.1055/a-2621-2515 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2025. Verfasst von Lisa van der Schee und 21 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, University Medical Centre Utrecht, Utrecht, Netherlands. Hauptthemen laut MEDLINE: Rectal Neoplasms, Magnetic Resonance Imaging, Endoscopic Mucosal Resection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Selection of rectal cancers suitable for endoscopic intermuscular dissection (EID) is challenging. We aimed to evaluate whether identification of ≥1 mm of preserved muscularis propria on magnetic resonance imaging (MRI), using a systematic reporting tool (mrSRT), can identify rectal cancers suitable for EID. An expert radiologist trained 12 study radiologists in the use of the mrSRT. The radiologists then assessed a retrospective series of MRIs from 269 consecutive patients with suspected deep submucosal invasive rectal cancer. The primary objective was to determine the diagnostic accuracy of ≥1 mm of preserved muscularis propria on MRI for selecting cases that can be resected with clear margins using EID (invasion limited to the circular muscularis propria [≤pT2circ]). Diagnostic accuracy was calculated for the expert radiologist, study radiologists, and a consensus diagnosis. After applying the inclusion and exclusion criteria, 244 patient scans were included in the analysis. Histological classification confirmed 18 lesions (7.4%) were noninvasive, 109 (44.7%) were pT1, 56 (23.0%) were pT2circ, 21 (8.6%) were pT2long, 39 (16.0%) were pT3, and 1 (0.4%) was pT4. The overall diagnostic accuracy of ≥1 mm of preserved muscularis propria as a criterion for selection was 80.7% (95%CI 75.2–85.5) for the expert radiologist, 77.5% (95%CI 71.7–82.5) for the trained study radiologists, and 81.6% (95%CI 76.1–86.2) for a consensus diagnosis. Use of mrSRT to identify ≥1 mm of preserved muscularis propria on MRI allowed radiologists to assist in appropriate case selection for EID.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rectal NeoplasmsMagnetic Resonance ImagingEndoscopic Mucosal ResectionHumansRetrospective StudiesMaleFemaleAgedMiddle AgedAged, 80 and overAdultIntestinal MucosaNeoplasm InvasivenessMargins of Excision

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, University Medical Centre Utrecht, Utrecht, Netherlands.
  • Department of Pathology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Department of Colorectal Surgery, Buckinghamshire Healthcare NHS Trust, Aylesbury, United Kingdom of Great Britain and Northern Ireland.
  • Department of Surgery and Cancer, Imperial College London, London, United Kingdom of Great Britain and Northern Ireland.
  • Department of Gastroenterology and Hepatology, Amsterdam University Medical Centers, Amsterdam, Netherlands.
  • Department of Radiology, Amsterdam University Medical Centers, Amsterdam, Netherlands.

ORCID-Profile: Lisa van der Schee

Zitieren

APA

van der Schee, L., Carten, R., Albers, S. C., van den Bergh, J., Braat, M. N. G. J. A., Goede, A. C., Kol, S., Lacle, M. M., Mearadji, B., Moos, S. I., Nota, I. M., Peters, N. H. G. M., Prince, J. F., Reimerink, J. J., Fariña Sarasqueta, A., van Vooren, J., van Waesberghe, J. H. T. M., Bastiaansen, B. A. J., Vleggaar, F. P., …, & Brown, G. (2025). Assessing the accuracy of magnetic resonance imaging in identifying early rectal cancers suitable for endoscopic intermuscular dissection. Endoscopy, 57(12), 1376-1385. https://doi.org/10.1055/a-2621-2515

Vancouver

van der Schee L, Carten R, Albers SC, van den Bergh J, Braat MNGJA, Goede AC, et al. Assessing the accuracy of magnetic resonance imaging in identifying early rectal cancers suitable for endoscopic intermuscular dissection. Endoscopy. 2025;57(12):1376-1385. doi:10.1055/a-2621-2515

BibTeX
@article{vanderSchee2025,
  author = {van der Schee, Lisa and Carten, Rachel and Albers, Sander C and van den Bergh, Janneke and Braat, Manon N G J A and Goede, Arnold C and Kol, Sabrine and Lacle, Miangela M and Mearadji, Banafsche and Moos, Shira I and Nota, Irene M and Peters, Nicky H G M and Prince, Jip F and Reimerink, Jorik J and Fariña Sarasqueta, Arantza and van Vooren, Jeanette and van Waesberghe, Jan Hein T M and Bastiaansen, Barbara A J and Vleggaar, Frank P and Moons, Leon M G and Horsthuis, Karin and Brown, Gina},
  title = {Assessing the accuracy of magnetic resonance imaging in identifying early rectal cancers suitable for endoscopic intermuscular dissection},
  journal = {Endoscopy},
  year = {2025},
  volume = {57},
  number = {12},
  pages = {1376--1385},
  doi = {10.1055/a-2621-2515}
}
Kostenlos starten →