EUVIMEDEUVIMED entdecken
Crossref

Association of Pregnancy-Adjusted Sepsis Screening Criteria with Risk of Maternal Infectious Morbidity in the Setting of Intrapartum Intraamniotic Infection

Zusammenhang von schwangerschaftsangepassten Sepsis-Screening-Kriterien mit dem Risiko mütterlicher Infektionsmorbidität bei intrapartaler intraamniotischer Infektion

Kathryn Ruymann, Eshika Agarwal, Martinique Ogle, Huda B Al-Kouatly, Rupsa C Boelig

American Journal of Perinatology · 01.10.2025 · 42 (14) · 1793-1797

DOI: 10.1055/a-2599-4813 ↗

Auf einen Blick

Bei 541 Gebärenden mit vermuteter intraamniotischer Infektion war ein positiver CMQCC-Sepsis-Screen in der Geburt mit mehr mütterlicher Infektionsmorbidität verbunden, jedoch nicht signifikant. Herz- und Atemfrequenz waren einzeln signifikant assoziiert.

Fragestellung

Wie gut sagt der erste Teil des CMQCC-Sepsis-Screens bei intraamniotischer Infektion eine infektiöse mütterliche Morbidität voraus?

Methode

Retrospektive Kohortenstudie an einem Zentrum mit 541 Patient:innen von Juli 2017 bis Juni 2021. Vergleich positiver versus negativer CMQCC-Sepsis-Screen; multivariable logistische Regression.

Ergebnisse

336/541 (62 %) screen-positive und 205/541 (38 %) screen-negative Fälle. Composite maternal infectious morbidity: 17,6 % vs. 11,7 %; p = 0,07; OR 1,6 (95 %-KI 0,96–2,68). Herzfrequenz >110 bpm: OR 2,1 (95 %-KI 1,3–3,4); Atemfrequenz >24 bpm: OR 5,7 (95 %-KI 1,09–29,8).

Schlussfolgerung der Autor:innen

Die Autor:innen schreiben, dass die meisten Gebärenden mit intraamniotischer Infektion vor der Geburt positiv gescreent wurden; erhöhte Herz- und Atemfrequenz könnten helfen, ein höheres Risiko zu erkennen.

Kernaussagen

  • Positiver Screen: 17,6 % vs. 11,7 % Infektionsmorbidität
  • Herzfrequenz >110 bpm und Atemfrequenz >24 bpm waren signifikant assoziiert
  • Retrospektive Einzelzentrumsstudie bei 541 Patient:innen

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Perinatology, erschienen am 01.10.2025. Verfasst von Kathryn Ruymann und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphi…. Hauptthemen laut MEDLINE: Sepsis, Pregnancy Complications, Infectious, Chorioamnionitis, Mass Screening. Die Arbeit nennt 13 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The California Maternal Quality Care Collaborative (CMQCC) developed a pregnancy-adjusted sepsis screen that includes temperature ≥100.4°F, heart rate > 110 bpm, respiratory rate > 24 bpm, and white blood cell count > 15,000/mm3. This tool was not validated in the intrapartum state. We aim to evaluate the performance of the first part of the CMQCC sepsis screen to identify infection-related morbidity in patients diagnosed with intraamniotic infection. A retrospective cohort study was performed of 541 patients diagnosed with suspected intraamniotic infection prior to delivery at a single center from July 2017 to June 2021. The primary outcome was composite maternal infectious morbidity (end-organ injury, bacteremia, intensive care unit admission, postpartum endometritis, postpartum readmission for infection, or maternal death) in birthing people who screened positive (two or more CMQCC sepsis screen criteria) compared with those who screened negative. Binary logistic multivariable regression was performed with backward selection including overall sepsis screen results as well as individual screening criteria. Data presented as odds ratio (OR) with a two-sided p-value of 0.05 was used for significance. Of the 541 reviewed cases, 336 (62%) screened positive while 205 (38%) screened negative. Birthing people with a positive sepsis screen in labor had a higher rate of composite maternal infectious morbidity compared with those with a negative screen, although this did not reach statistical significance (17.6% vs. 11.7%; p = 0.07; OR: 1.6 [0.96–2.68]). In evaluating individual criteria, heart rate > 110 bpm (p = 0.003; OR: 2.1 [1.3–3.4]) and respiratory rate > 24 bpm (p = 0.039; 5.7 [1.09–29.8]) were significantly associated with composite maternal infectious morbidity. Most birthing people with intraamniotic infection screen positive prior to delivery using the CMQCC sepsis screen. When looking at the sepsis screen's individual components, elevated heart rate and respiratory rate may be useful in identifying those at increased risk of infectious morbidity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SepsisPregnancy Complications, InfectiousChorioamnionitisMass ScreeningHumansFemalePregnancyRetrospective StudiesAdultLogistic ModelsEndometritisRespiratory RateLeukocyte Count

Autor:innen und Institutionen

  • Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania.
  • Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania.

Zitieren

APA

Ruymann, K., Agarwal, E., Ogle, M., Al-Kouatly, H. B., & Boelig, R. C. (2025). Association of Pregnancy-Adjusted Sepsis Screening Criteria with Risk of Maternal Infectious Morbidity in the Setting of Intrapartum Intraamniotic Infection. American Journal of Perinatology, 42(14), 1793-1797. https://doi.org/10.1055/a-2599-4813

Vancouver

Ruymann K, Agarwal E, Ogle M, Al-Kouatly HB, Boelig RC. Association of Pregnancy-Adjusted Sepsis Screening Criteria with Risk of Maternal Infectious Morbidity in the Setting of Intrapartum Intraamniotic Infection. American Journal of Perinatology. 2025;42(14):1793-1797. doi:10.1055/a-2599-4813

BibTeX
@article{Ruymann2025,
  author = {Ruymann, Kathryn and Agarwal, Eshika and Ogle, Martinique and Al-Kouatly, Huda B and Boelig, Rupsa C},
  title = {Association of Pregnancy-Adjusted Sepsis Screening Criteria with Risk of Maternal Infectious Morbidity in the Setting of Intrapartum Intraamniotic Infection},
  journal = {American Journal of Perinatology},
  year = {2025},
  volume = {42},
  number = {14},
  pages = {1793--1797},
  doi = {10.1055/a-2599-4813}
}
Kostenlos starten →