Endoscopic ultrasound-directed transenteric retrograde cholangiopancreatography using a new slim scope with an operative working channel
Endoscopy · 01.12.2025 · 57 (S 01 S 01) · E576-E577
DOI: 10.1055/a-2598-3729 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2025. Verfasst von Marco Spadaccini und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology and Digestive Endoscopy, IRCCS Humanitas Research Hospital, Rozzano, Italy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A 79-year-old man, with a history of total gastrectomy with esophagojejunostomy on a Roux-en-Y loop for T2N0 adenocarcinoma, was admitted because of abdominal pain and elevated levels on his liver function tests. A computed tomography (CT) scan showed a stone in the common bile duct (CBD). An entero-endoscopic retrograde cholangiopancreatography was attempted with a long pediatric scope using the underwater cap-assisted technique [ 1 ], but we failed to reached the papillary region owing to the length of the biliary loop. A 7-Fr endoscopic catheter was advanced through the scope back to the proximal jejunum and left in place to facilitate the next steps [ 2 ]. Using a linear operative echoendoscope, we identified the duodenal loop, but were then unable to distend it by injecting contrast and fluid through the endoscopic catheter ([ Fig. 1 ]), so the direct needle-puncture technique was instead used to distend the duodenal loop [ 3 ] [ 4 ]. Once the target loop was sufficiently distended, an entero-enteric anastomosis was created by placing a 15 × 10-mm lumen-apposing metal stent (LAMS) [ 5 ] ([ Fig. 2 ]). Fig. 1 Endoscopic ultrasound image showing the instillation of contrast and saline with methylene blue via a nasojejunostomy tube at the level of the efferent loop of the anastomosis, with correct positioning being confirmed by the aspiration of methylene blue with a 19G needle. Fig. 2 Endoscopic image showing the lumen-apposing metal stent (15 × 10 mm) that was placed to create the entero-enteric anastomosis. The patient was discharged on the following day, then readmitted 2 weeks after the index procedure, when a new slim gastroscope with a 7.9-mm outer diameter and a therapeutic working channel of 3.2 mm was used to reach the papillary region through the LAMS. Using a catheter and hydrophilic guidewire ([ Fig. 3 ]), we were able to selectively cannulate the CBD. Pneumatic dilation of the papilla was performed ([ Fig. 4 ]), and complete clearance of the biliary tract was achieved using an extraction balloon (9–12 mm) ([ Fig. 5 ]; [ Video 1 ]). The LAMS was subsequently removed 1 month later without any adverse events. Fig. 3 Fluoroscopic image showing cannulation of the bile duct using a forward-viewing scope with a catheter and hydrophilic guidewire. Fig. 4 Endoscopic image showing pneumatic dilation of the papilla up to 9 mm using an extraction balloon (CRE). Fig. 5 Fluoroscopic image showing clearance of the bile duct using an extraction balloon (9–12 mm). Download Endoscopic ultrasound-directed transenteric endoscopic retrograde cholangiopancreatography is performed by placing a lumen-apposing metal stent (15 × 10 mm) and using a forward-viewing scope to perform pneumatic dilation of the papilla up to 9 mm and clearance of the bile duct with an extraction balloon.Video 1 Endoscopy_UCTN_Code_TTT_1AS_2AH Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 13 June 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Autor:innen und Institutionen
- Division of Gastroenterology and Digestive Endoscopy, IRCCS Humanitas Research Hospital, Rozzano, Italy.
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy.
ORCID-Profile: Alessandro Fugazza, Cesare Hassan
Zitieren
APA
Spadaccini, M., Fugazza, A., De Marco, A., Colombo, M., Craviotto, V., Hassan, C., & Repici, A. (2025). Endoscopic ultrasound-directed transenteric retrograde cholangiopancreatography using a new slim scope with an operative working channel. Endoscopy, 57(S 01 S 01), E576-E577. https://doi.org/10.1055/a-2598-3729
Vancouver
Spadaccini M, Fugazza A, De Marco A, Colombo M, Craviotto V, Hassan C, et al. Endoscopic ultrasound-directed transenteric retrograde cholangiopancreatography using a new slim scope with an operative working channel. Endoscopy. 2025;57(S 01 S 01):E576-E577. doi:10.1055/a-2598-3729
BibTeX
@article{Spadaccini2025,
author = {Spadaccini, Marco and Fugazza, Alessandro and De Marco, Alessandro and Colombo, Matteo and Craviotto, Vincenzo and Hassan, Cesare and Repici, Alessandro},
title = {Endoscopic ultrasound-directed transenteric retrograde cholangiopancreatography using a new slim scope with an operative working channel},
journal = {Endoscopy},
year = {2025},
volume = {57},
number = {S 01 S 01},
pages = {E576--E577},
doi = {10.1055/a-2598-3729}
}
EUVIMED