EUVIMEDEUVIMED entdecken
Crossref

Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs

Adan Peres Cabreira iD, Gabriel Antonio Covino Diamante, Thales Bregadioli, Mônica Vicky Bahr Arias

Veterinary and Comparative Orthopaedics and Traumatology · 01.01.2026 · 39 (01) · 014-020

DOI: 10.1055/a-2551-3374 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.01.2026. Verfasst von Adan Peres Cabreira und 3 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Clínicas Veterinárias da Universidade Estadual de Londrina, PR, Brasil. Hauptthemen laut MEDLINE: Atlanto-Axial Joint, Dog Diseases, Joint Instability, Prostheses and Implants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To develop a patient-specific implant designed for dorsal access instrumentation, which also serves as a guide for screw insertion, for use in dogs with atlantoaxial instability. The implant must demonstrate no failure in finite element analysis. The development of an implant utilizing computational resources based on a computed tomography scan of a patient with atlantoaxial instability. The final implant model was analysed using finite element methods in flexion, extension, lateral flexion, and torsion to evaluate stress distribution and displacement. A patient-specific implant for dorsal instrumentation was developed, featuring six holes for the insertion of 1.7-mm bicortical locking screws, including two transarticular screws and two additional screws per vertebra. The implant demonstrated a maximum stress point of 425 MPa, well below the material yield strength of 880 MPa, with a maximum displacement of only 0.13 mm. The proposed implant shows promise as it can function as a drilling guide, potentially enhancing safety during instrumentation. Using safe corridors may improve the rigidity of the construct. The implant model did not exhibit any failure when subjected to finite element analysis according to the established criteria.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atlanto-Axial JointDog DiseasesJoint InstabilityProstheses and ImplantsAnimalsDogsFinite Element AnalysisBone ScrewsBiomechanical PhenomenaTomography, X-Ray Computed

Autor:innen und Institutionen

  • Departamento de Clínicas Veterinárias da Universidade Estadual de Londrina, PR, Brasil.
  • Orthosupport Pet Centro Especializado em Neurologia e Ortopedia, Campinas, SP, Brasil.

ORCID-Profile: Adan Peres Cabreira

Zitieren

APA

Cabreira, A. P., Diamante, G. A. C., Bregadioli, T., & Bahr Arias, M. V. (2026). Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs. Veterinary and Comparative Orthopaedics and Traumatology, 39(01), 014-020. https://doi.org/10.1055/a-2551-3374

Vancouver

Cabreira AP, Diamante GAC, Bregadioli T, Bahr Arias MV. Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs. Veterinary and Comparative Orthopaedics and Traumatology. 2026;39(01):014-020. doi:10.1055/a-2551-3374

BibTeX
@article{Cabreira2026,
  author = {Cabreira, Adan Peres and Diamante, Gabriel Antonio Covino and Bregadioli, Thales and Bahr Arias, Mônica Vicky},
  title = {Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2026},
  volume = {39},
  number = {01},
  pages = {014--020},
  doi = {10.1055/a-2551-3374}
}
Kostenlos starten →