EUVIMEDEUVIMED entdecken
Crossref

Improving First-Attempt Intubation Success Rate in a Level IV Neonatal Intensive Care Unit Through the Use of a Video Laryngoscope: A Quality Improvement Initiative

Verbesserung der ersten Intubationsversuchsrate auf einer Level-IV-Neonatal-Intensivstation durch den Einsatz eines Videolaryngoskops: Qualitätsverbesserungsinitiative

Stephanie Martinez iD, Monika Bhola, Nori Mercuri Minich, Charlene Nauman, Kathleen Deakins, Allison Oliverio, Gulgun Yalcinkaya

American Journal of Perinatology · 2025-10 · 42 (13) · 1743-1753

DOI: 10.1055/a-2533-2465 ↗

Auf einen Blick

In einer Level-IV-NICU stieg die Erfolgsrate beim ersten Intubationsversuch unter Einführung eines Videolaryngoskops von 45 auf 57 %.

Fragestellung

Lässt sich die Erfolgsrate beim ersten Intubationsversuch in einer Level-IV-NICU durch Einführung und häufigere Nutzung eines Videolaryngoskops verbessern?

Methode

Qualitätsverbesserungsinitiative mit Model for Improvement und Plan-Do-Study-Act-Zyklen; Daten zu 418 Intubationen von November 2021 bis April 2024.

Ergebnisse

418 Intubationen. Die erste Erfolgsrate beim Intubationsversuch stieg während des Interventionszeitraums von 45 % auf 57 %.

Schlussfolgerung der Autor:innen

Die erfolgreiche Implementierung eines Videolaryngoskops im klinischen Alltag erhöhte die Erfolgsrate beim ersten Intubationsversuch in der NICU.

Kernaussagen

  • 418 Intubationen wurden ausgewertet.
  • Erfolgsrate beim ersten Versuch: 45 % vor, 57 % während der Intervention.
  • Die Einführung erfolgte gestaffelt mit Referenzmaterialien und Coachings.

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Perinatology, online erschienen am 06.03.2025. Verfasst von Stephanie Martinez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neonatology, University Hospitals of Cleveland, Rainbow Babies and Children's Hospital, Cleveland, Ohio. Hauptthemen laut MEDLINE: Quality Improvement, Intubation, Intratracheal, Intensive Care Units, Neonatal, Laryngoscopes. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Hearst Funds.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

There is increasing evidence that the use of a video laryngoscope improves first-attempt intubation rates in neonates. The goal of this quality improvement initiative was to improve the first-attempt intubation success rate from 45 to 65% in 2.5 years through the introduction and increased use of a video laryngoscope in a level IV neonatal intensive care unit (NICU). We utilized the Model for Improvement with plan-do-study-act cycles targeted at increasing buy-in and comfort with the use of a video laryngoscope. Data on 418 intubations were collected from November 2021 to April 2024. Through increasing routine use of the video laryngoscope, achieved via a staggered introduction of the device, creation of reference materials, and coaching workshops, we improved the overall first-attempt intubation success rate from 45 to 57% during the intervention period. We increased the first-attempt success rate of intubations in the NICU by effectively implementing the use of a video laryngoscope into daily practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quality ImprovementIntubation, IntratrachealIntensive Care Units, NeonatalLaryngoscopesLaryngoscopyHumansInfant, NewbornVideo RecordingFemale

Autor:innen und Institutionen

  • Division of Neonatology, University Hospitals of Cleveland, Rainbow Babies and Children's Hospital, Cleveland, Ohio.
  • Division of Neonatology, Department of Pediatrics, College of Medicine, University of Tennessee Health Science Center, Memphis, Tennessee.
  • Department of Pediatrics, Case Western Reserve University, Cleveland, Ohio.

ORCID-Profile: Stephanie Martinez

Förderung

  • Hearst Funds

Zitieren

APA

Martinez, S., Bhola, M., Minich, N. M., Nauman, C., Deakins, K., Oliverio, A., & Yalcinkaya, G. (2025). Improving First-Attempt Intubation Success Rate in a Level IV Neonatal Intensive Care Unit Through the Use of a Video Laryngoscope: A Quality Improvement Initiative. American Journal of Perinatology, 42(13), 1743-1753. https://doi.org/10.1055/a-2533-2465

Vancouver

Martinez S, Bhola M, Minich NM, Nauman C, Deakins K, Oliverio A, et al. Improving First-Attempt Intubation Success Rate in a Level IV Neonatal Intensive Care Unit Through the Use of a Video Laryngoscope: A Quality Improvement Initiative. American Journal of Perinatology. 2025;42(13):1743-1753. doi:10.1055/a-2533-2465

BibTeX
@article{Martinez2025,
  author = {Martinez, Stephanie and Bhola, Monika and Minich, Nori Mercuri and Nauman, Charlene and Deakins, Kathleen and Oliverio, Allison and Yalcinkaya, Gulgun},
  title = {Improving First-Attempt Intubation Success Rate in a Level IV Neonatal Intensive Care Unit Through the Use of a Video Laryngoscope: A Quality Improvement Initiative},
  journal = {American Journal of Perinatology},
  year = {2025},
  volume = {42},
  number = {13},
  pages = {1743--1753},
  doi = {10.1055/a-2533-2465}
}
Kostenlos starten →