EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Hybrid percutaneous endoscopic gastrostomy (Hybrid PEG) improves patient safety by combining pull-through technique with gastropexy

Hybride perkutane endoskopische Gastrostomie (Hybrid-PEG) verbessert die Patientensicherheit durch Kombination von Pull-through-Technik und Gastropexie

Tobias Horst Kinzel, Viktoria Reich, Leonie Schuhmacher, Christian Bojarski, Andreas Adler, Wielfried Veltzke-Schlieker, Christian Jürgensen, Frank Tacke, Britta Siegmund, Juliane Buchkremer, Federica Branchi, Christoph Treese iD

Endoscopy International Open · 26.02.2025 · 13 (CP)

DOI: 10.1055/a-2511-2096 ↗

Auf einen Blick

In einer retrospektiven Kohorte war Hybrid-PEG ebenso sicher wie die Direktpunktion. Beide Verfahren waren sicherer als die Pull-through-Technik.

Fragestellung

Wie sicher ist Hybrid-PEG im Vergleich zu Direktpunktion und Pull-through-Technik bei der PEG-Anlage?

Methode

Retrospektive Kohortenstudie in einem Endoskopiezentrum; Daten von Januar 2016 bis Dezember 2021; Vergleich von Hybrid-PEG, Direktpunktion und Pull-through-Technik.

Ergebnisse

351 Patient:innen mit Hybrid-PEG, 145 mit Direktpunktion und 1073 mit Pull-through-Technik. Mit Gastropexie gab es keine signifikanten Unterschiede bei schweren und leichten Komplikationen. Pull-through zeigte eine fünfmal höhere Rate schwerer und eine doppelt so hohe Rate leichter Komplikationen; OR 0,166 (0,084–0,329; P < 0,001) für schwere Komplikationen.

Einschränkungen

Retrospektives Design.

Schlussfolgerung der Autor:innen

Hybrid-PEG und Direktpunktion sind gleich sichere PEG-Anlagen und haben bessere Sicherheitsprofile als die Pull-through-Technik. Die Autor:innen sehen trotz retrospektiver Daten einen bevorzugten Einsatz von Hybrid-PEG wegen der Handhabung.

Kernaussagen

  • Hybrid-PEG und Direktpunktion waren gleich sicher
  • Pull-through hatte mehr schwere und leichte Komplikationen
  • Gastropexie war mit weniger schweren Komplikationen assoziiert

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 26.02.2025. Verfasst von Tobias Horst Kinzel und 11 weiteren Autor:innen. Beteiligte Einrichtung: Medizinische Klinik für Gastroenterologie, Infektiologie und Rheumatologie, Charité - Universitätsmedizin Berlin, corporate member of Freie Universit…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The direct puncture technique has been associated with a better safety profile compared with the classical pull-through technique for insertion of a percutaneous endoscopic gastrostomy (PEG). In this study, the safety of the hybrid PEG technique, combining gastropexy with the pull-through technique, was analyzed in a large retrospective patient cohort. Clinical data from patients undergoing PEG insertion in a high-volume center for endoscopy were included retrospectively between January 2016 and December 2021. Patient characteristics and complication rates were correlated in univariate and multivariate analyses. Data from 351 patients undergoing PEG insertion with the hybrid PEG technique were compared with 145 procedures with the direct puncture technique and 1073 procedures with the pull-through technique. In the group where gastropexy was performed (hybrid PEG and direct puncture), we could not find any significant differences in frequency of major and minor complications. Comparing the pull-through technique with the gastropexy group, we detected a five-fold higher major complication rate and a doubled minor complication rate for the pull-through technique. Multivariate analysis confirmed the protective role of gastropexy, with an odds ratio of 0.166 (0.084–0.329; P < 0.001) for major complications. Hybrid PEG and direct puncture are equally safe PEG insertion techniques, with significantly better safety profiles than the pull-through technique. Despite the retrospective design of the study, these results suggest preferential use of hybrid PEG due to handling.

Schlagwörter

Stichwörter der Autor:innen

Endoscopy Upper GI TractGastrostomy and PEJPerformance and complicationsQuality and logistical aspects

Autor:innen und Institutionen

  • Medizinische Klinik für Gastroenterologie, Infektiologie und Rheumatologie, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
  • Medizinische Klinik mit Schwerpunkt Hepatologie und Gastroenterologie, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.

ORCID-Profile: Christoph Treese

Zitieren

APA

Kinzel, T. H., Reich, V., Schuhmacher, L., Bojarski, C., Adler, A., Veltzke-Schlieker, W., Jürgensen, C., Tacke, F., Siegmund, B., Buchkremer, J., Branchi, F., & Treese, C. (2025). Hybrid percutaneous endoscopic gastrostomy (Hybrid PEG) improves patient safety by combining pull-through technique with gastropexy. Endoscopy International Open, 13(CP). https://doi.org/10.1055/a-2511-2096

Vancouver

Kinzel TH, Reich V, Schuhmacher L, Bojarski C, Adler A, Veltzke-Schlieker W, et al. Hybrid percutaneous endoscopic gastrostomy (Hybrid PEG) improves patient safety by combining pull-through technique with gastropexy. Endoscopy International Open. 2025;13(CP). doi:10.1055/a-2511-2096

BibTeX
@article{Kinzel2025,
  author = {Kinzel, Tobias Horst and Reich, Viktoria and Schuhmacher, Leonie and Bojarski, Christian and Adler, Andreas and Veltzke-Schlieker, Wielfried and Jürgensen, Christian and Tacke, Frank and Siegmund, Britta and Buchkremer, Juliane and Branchi, Federica and Treese, Christoph},
  title = {Hybrid percutaneous endoscopic gastrostomy (Hybrid PEG) improves patient safety by combining pull-through technique with gastropexy},
  journal = {Endoscopy International Open},
  year = {2025},
  volume = {13},
  number = {CP},
  doi = {10.1055/a-2511-2096}
}
Kostenlos starten →