Intrapartum Glycemic Control with Insulin Infusion versus Rotating Fluids: A Randomized Controlled Trial
American Journal of Perinatology · 01.08.2025 · 42 (11) · 1491-1499
DOI: 10.1055/a-2510-4906 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift American Journal of Perinatology, erschienen am 01.08.2025. Verfasst von Maranda Sullivan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Maternal-Fetal Medicine, Geisinger Medical Center, Danville, Pennsylvania. Hauptthemen laut MEDLINE: Insulin, Diabetes, Gestational, Hypoglycemic Agents, Glycemic Control. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
This study aimed to evaluate rotating intravenous (IV) fluids compared with insulin infusion for maternal intrapartum glycemic control of neonatal blood glucose within 2 hours of birth. This randomized controlled trial compared the use of rotating IV fluids to continuous insulin infusion for intrapartum glycemic control for patients with type II diabetes mellitus (DM) or medication-controlled gestational diabetes (A2GDM). A sample size of 74 participants was studied to detect a 10-mg/dL difference in neonatal blood glucose within 2 hours of birth between the groups with a standard deviation of 15, 80% power, and α 0.05. Secondary neonatal outcomes included neonatal blood glucose within 24 hours after birth, Apgar < 7 at 5 minutes, and a composite including neonatal hypoglycemia, NICU admission, hyperbilirubinemia, and respiratory distress syndrome. Secondary maternal outcomes included intrapartum hypoglycemia, blood glucose immediately prior to delivery, mode of delivery, and postpartum complications. Both intention-to-treat (ITT) and per-protocol (PP) analyses were performed. A total of 114 patients were randomized, 57 in each arm. For the PP analysis, 51 patients were analyzed in the rotating IV fluids arm and 32 patients in the insulin infusion arm. There was no significant difference in neonatal blood glucose within 2 hours of birth when rotating IV fluids were used (ITT: 54.5 mg/dL [IQR: 42.5, 72.5], PP: 56.0 mg/dL [IQR: 42.0, 76.0]) when compared with an insulin infusion (ITT: 59.0 mg/dL [IQR: 41.0, 69.0], PP: 62.5 mg/dL [IQR: 44.5, 68.5], p = 0.89 [ITT] and p = 0.68 [PP]). No significant differences were noted in secondary outcomes. The median intrapartum maternal blood glucose was 98.5 mg/dL (IQR: 90.5, 105.0) in the rotating fluids arm and 96.3 mg/dL (IQR: 90.0, 108.5) in the insulin infusion arm (p = 0.96), and the rate of neonatal hypoglycemia was 11.8 versus 15.6%, respectively (p = 0.61) in the PP analysis. There was no difference in neonatal blood glucose within 2 hours of birth when rotating IV fluids were used for intrapartum glycemic control compared with a continuous insulin infusion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Maternal-Fetal Medicine, Geisinger Medical Center, Danville, Pennsylvania.
- Department of Population Health Sciences, Geisinger Medical Center, Danville, Pennsylvania.
Zitieren
APA
Sullivan, M., Angras, K., Boyd, V., Young, A. J., Mackeen, A. D., & Paglia, M. J. (2025). Intrapartum Glycemic Control with Insulin Infusion versus Rotating Fluids: A Randomized Controlled Trial. American Journal of Perinatology, 42(11), 1491-1499. https://doi.org/10.1055/a-2510-4906
Vancouver
Sullivan M, Angras K, Boyd V, Young AJ, Mackeen AD, Paglia MJ. Intrapartum Glycemic Control with Insulin Infusion versus Rotating Fluids: A Randomized Controlled Trial. American Journal of Perinatology. 2025;42(11):1491-1499. doi:10.1055/a-2510-4906
BibTeX
@article{Sullivan2025,
author = {Sullivan, Maranda and Angras, Kajal and Boyd, Victoria and Young, Amanda J and Mackeen, A Dhanya and Paglia, Michael J},
title = {Intrapartum Glycemic Control with Insulin Infusion versus Rotating Fluids: A Randomized Controlled Trial},
journal = {American Journal of Perinatology},
year = {2025},
volume = {42},
number = {11},
pages = {1491--1499},
doi = {10.1055/a-2510-4906}
}