EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A novel technique for colonic diverticular bleeding hemostasis using hemostatic forceps and the reopenable-clip over-the-line method

Junki Toyoda, Tatsuma Nomura iD, Takanobu Mitani, Yuto Ikadai, Tomohiro Sase, Tomonori Saito, Katsumi Mukai

Endoscopy · 01.12.2025 · 57 (S 01 S 01) · E36-E37

DOI: 10.1055/a-2505-9253 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2025. Verfasst von Junki Toyoda und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Suzuka General Hospital, Suzuka, Japan. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Colonic diverticular bleeding is the most common cause of acute lower gastrointestinal bleeding. Although colorectal endoscopic submucosal dissection has spread throughout the world, and hemostasis with hemostatic forceps for the vessels within the diverticulum has become common, the use of hemostatic forceps for diverticular bleeding is not common due to the risk of perforation [ 1 ]. We propose the use of a calibrated, small-caliber tip, transparent hood with a tapered 4-mm tip (CAST hood; TOP, Tokyo, Japan) to identify bleeding in small diverticula [ 2 ]. We report a novel method of closure for small diverticular bleeding in the ascending colon using the reopenable-clip over-the-line method (ROLM), which allows complete closure of the diverticulum after postoperative vascular coagulation with hemostatic forceps ([ Fig. 1 ], [ Video 1 ]) [ 3 ]. Fig. 1 Hemostatic forceps and the reopenable-clip over-the-line method (ROLM) to achieve hemostasis in diverticular bleeding. a Diverticulum with active bleeding after removal of clots. b A bleeding point in the center of the diverticulum. c, d Coagulation of the bleeding point with hemostatic forceps. e First clip with line placed at the edge of the diverticulum. f A reopenable clip with a line through the tooth is placed at the contralateral defect edge. g A reopenable clip with a line through the tooth was repeatedly placed on the contralateral diverticular edge. h Diverticulum completely closed with a total of eight clips after coagulation and hemostasis of the bleeding point. Quality: mobile 360 480 720 Download Hemostatic forceps and a reopenable-clip over-the-line method for hemostasis of diverticular bleeding.Video 1 ROLM is a defect closure method that uses a reopenable clip (SureClip 8 mm; Micro-Tech [Nanjing] Co. Ltd., Nanjing, China) and a line (0.22 mm, polyethylene line), which can be combined with a narrow 4-mm CAST hood to achieve complete mucosal defect closure even in narrow spaces [ 4 ] [ 5 ]. A 56-year-old man presented to our hospital as an outpatient with bloody stools. After preparation, a colonoscopy was performed using a CAST hood to identify the bleeding point, although no active bleeding was observed. A small diverticulum with blood clots was found in the ascending colon and active bleeding was observed after the clots were removed. Initially, a marking clip was placed near the diverticulum. Because the diverticulum was small (approximately 6 mm) and had a bleeding point at its center, hemostatic forceps were used to coagulate the blood vessels. After confirming disappearance of the bleeding point, the diverticulum was completely closed using ROLM to prevent perforation and rebleeding during the postoperative period. A clip with a line was placed at the diverticulum edge. The patient was discharged without adverse events or bleeding from the diverticulum. Endoscopy_UCTN_Code_TTT_1AQ_2AZ Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 16 January 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Autor:innen und Institutionen

  • Department of Gastroenterology, Suzuka General Hospital, Suzuka, Japan.
  • Department of Endoscopy Center, Suzuka General Hospital, Suzuka, Japan.

ORCID-Profile: Tatsuma Nomura

Zitieren

APA

Toyoda, J., Nomura, T., Mitani, T., Ikadai, Y., Sase, T., Saito, T., & Mukai, K. (2025). A novel technique for colonic diverticular bleeding hemostasis using hemostatic forceps and the reopenable-clip over-the-line method. Endoscopy, 57(S 01 S 01), E36-E37. https://doi.org/10.1055/a-2505-9253

Vancouver

Toyoda J, Nomura T, Mitani T, Ikadai Y, Sase T, Saito T, et al. A novel technique for colonic diverticular bleeding hemostasis using hemostatic forceps and the reopenable-clip over-the-line method. Endoscopy. 2025;57(S 01 S 01):E36-E37. doi:10.1055/a-2505-9253

BibTeX
@article{Toyoda2025,
  author = {Toyoda, Junki and Nomura, Tatsuma and Mitani, Takanobu and Ikadai, Yuto and Sase, Tomohiro and Saito, Tomonori and Mukai, Katsumi},
  title = {A novel technique for colonic diverticular bleeding hemostasis using hemostatic forceps and the reopenable-clip over-the-line method},
  journal = {Endoscopy},
  year = {2025},
  volume = {57},
  number = {S 01 S 01},
  pages = {E36--E37},
  doi = {10.1055/a-2505-9253}
}
Kostenlos starten →