EUVIMEDEUVIMED entdecken
Open Access

High-Resolution Vessel Wall Imaging for Treatment Sequencing of Multiple Aneurysms in Subarachnoid Hemorrhage

Lea Scherschinski, Christopher S Graffeo iD, Joelle N Hartke, Ashia M Hackett, Joshua S Catapano, Visish M Srinivasan, Michael T Lawton

Journal of Neurological Surgery Part B: Skull Base · 01.02.2026 · 87 (01) · 023-028

DOI: 10.1055/a-2505-7850 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neurological Surgery Part B: Skull Base, erschienen am 01.02.2026. Verfasst von Lea Scherschinski und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, United States. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Approximately 30% of patients with subarachnoid hemorrhage (SAH) present with multiple aneurysms. Identifying the ruptured aneurysm is often difficult, and not all lesions may be accessible through a single craniotomy. Magnetic resonance high-resolution vessel wall imaging (HR-VWI) is an innovative imaging modality that identifies aneurysm wall instability. Technical note and literature review with an illustrative case report and operative videos. Outpatient, inpatient, and operating room of a quaternary neurosurgical referral center. SAH was diagnosed in a woman in her early 40s presenting with headache and left arm paresthesias. HR-VWI for treatment sequencing of multiple aneurysms in SAH. Two saccular aneuryms were identified, arising from the right posterior inferior cerebellar artery (PICA) and basilar artery (BA) bifurcation. HR-VWI suggested the PICA aneurysm as the probable SAH source. Treatment recommendations were far lateral craniotomy for PICA aneurysm clipping, followed by staged orbitozygomatic craniotomy for BA aneurysm clipping at 3 months. Both procedures resulted in successful clip reconstruction of the aneurysm and an excellent neurological outcome. Effective management of SAH patients with multiple aneurysms demands specialized diagnostic and surgical strategies. Rapid, precise identification of the SAH source is imperative, as is comprehensive treatment of all aneurysms. Key educational findings include management pearls for patients with multiple aneurysms, SAH localization with HR-VWI, the importance of inspecting the circle of Willis in patients at high risk, and technical insights for PICA and BA aneurysm clipping.

Schlagwörter

Stichwörter der Autor:innen

basilar arterycerebral aneurysmmicrosurgeryposterior inferior cerebellar arterysubarachnoid hemorrhagevessel wall imaging

Autor:innen und Institutionen

  • Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, United States.

ORCID-Profile: Christopher S Graffeo

Zitieren

APA

Scherschinski, L., Graffeo, C. S., Hartke, J. N., Hackett, A. M., Catapano, J. S., Srinivasan, V. M., & Lawton, M. T. (2026). High-Resolution Vessel Wall Imaging for Treatment Sequencing of Multiple Aneurysms in Subarachnoid Hemorrhage. Journal of Neurological Surgery Part B: Skull Base, 87(01), 023-028. https://doi.org/10.1055/a-2505-7850

Vancouver

Scherschinski L, Graffeo CS, Hartke JN, Hackett AM, Catapano JS, Srinivasan VM, et al. High-Resolution Vessel Wall Imaging for Treatment Sequencing of Multiple Aneurysms in Subarachnoid Hemorrhage. Journal of Neurological Surgery Part B: Skull Base. 2026;87(01):023-028. doi:10.1055/a-2505-7850

BibTeX
@article{Scherschinski2026,
  author = {Scherschinski, Lea and Graffeo, Christopher S and Hartke, Joelle N and Hackett, Ashia M and Catapano, Joshua S and Srinivasan, Visish M and Lawton, Michael T},
  title = {High-Resolution Vessel Wall Imaging for Treatment Sequencing of Multiple Aneurysms in Subarachnoid Hemorrhage},
  journal = {Journal of Neurological Surgery Part B: Skull Base},
  year = {2026},
  volume = {87},
  number = {01},
  pages = {023--028},
  doi = {10.1055/a-2505-7850}
}
Kostenlos starten →