EUVIMEDEUVIMED entdecken
Open Access

Validation of a New Clinical Test for Diagnosis of Trapeziometacarpal Arthritis

Alvaro Antonio Kafury iD, María Elisa Novillo, Fredy Angarita, Jhon Freddy Castañeda, Juliana Andrea Rojas, Sandra Patricia Muñoz

Journal of Wrist Surgery · 01.04.2026 · 15 (02) · e1-e6

DOI: 10.1055/a-2498-0718 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Wrist Surgery, erschienen am 01.04.2026. Verfasst von Alvaro Antonio Kafury und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Clínica Imbanaco, Grupo Quirónsalud, Pontificia Universidad Javeriana, Cali, Colombia. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Symptomatic trapeziometacarpal arthrosis is primarily diagnosed on clinical grounds. The X-ray appearance correlates poorly with the presence and severity of pain; therefore, radiography is not a useful tool to define which patient is symptomatic, nor which one should be treated. There is not a specific gold standard test. The grind test is the most used clinical test; however, its level of diagnostic accuracy is not very high. The aim of this study is to describe and validate a new clinical test. Materials and Methods A prospective study was conducted to evaluate the diagnostic performance and reliability of the compression and flexion test.

Results

A total of 106 patients were included. Excellent interobserver agreement was found for both semiology tests (kappa = 0.82 and intraclass correlation coefficient = 0.97). The area under the curve for the compression and flexion test showed an estimate of 99.2 (95% confidence interval [CI]: 97.6–100) and for the grind test of 62 (95% CI: 51.2–71.9). The diagnostic performance of the compression and flexion test showed a sensitivity of 100% (95% CI: 92.1–99.9) and a specificity of 98.4% (95% CI: 91.2–100), in contrast to the grind test that reports a sensitivity of 22.2% (95% CI: 11.2–37.1) and a specificity of 93.4% [95% CI: 84.1–98.2].

Conclusions

The diagnostic performance of the compression and flexion test is higher than that of the grind test. Furthermore, the results show an excellent interobserver correlation and diagnostic accuracy, making it a useful clinical tool for the diagnosis of trapeziometacarpal arthritis. Type of Study/Level of Evidence Diagnostic tests II.

Schlagwörter

Stichwörter der Autor:innen

arthrosis of the thumbcompression and flexion testdiagnostic testgrind testphysical examrhizarthrosisthumbthumb base arthrosistrapeziometacarpal joint

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Clínica Imbanaco, Grupo Quirónsalud, Pontificia Universidad Javeriana, Cali, Colombia.
  • Department of Orthopaedic Surgery, Clínica Imbanaco, Grupo Quirónsalud, Cali, Colombia.
  • Department of Hand Surgery, Clínica Portoazul, Barranquilla, Colombia.
  • Department of Orthopaedic Surgery, Hospital Universitario Nacional de Colombia, Bogotá, Colombia.
  • Department of Radiology, Clínica Imbanaco, Grupo Quirónsalud Cali, Cali, Colombia.

ORCID-Profile: Alvaro Antonio Kafury

Zitieren

APA

Kafury, A. A., Novillo, M. E., Angarita, F., Castañeda, J. F., Rojas, J. A., & Muñoz, S. P. (2026). Validation of a New Clinical Test for Diagnosis of Trapeziometacarpal Arthritis. Journal of Wrist Surgery, 15(02), e1-e6. https://doi.org/10.1055/a-2498-0718

Vancouver

Kafury AA, Novillo ME, Angarita F, Castañeda JF, Rojas JA, Muñoz SP. Validation of a New Clinical Test for Diagnosis of Trapeziometacarpal Arthritis. Journal of Wrist Surgery. 2026;15(02):e1-e6. doi:10.1055/a-2498-0718

BibTeX
@article{Kafury2026,
  author = {Kafury, Alvaro Antonio and Novillo, María Elisa and Angarita, Fredy and Castañeda, Jhon Freddy and Rojas, Juliana Andrea and Muñoz, Sandra Patricia},
  title = {Validation of a New Clinical Test for Diagnosis of Trapeziometacarpal Arthritis},
  journal = {Journal of Wrist Surgery},
  year = {2026},
  volume = {15},
  number = {02},
  pages = {e1--e6},
  doi = {10.1055/a-2498-0718}
}
Kostenlos starten →