Multiparametric functional MRI of the kidneys – evaluation of test-retest repeatability and effects of different manual and automatic image analysis strategies

Cecilia Liang iD, Isabelle Loster, Stephan Ursprung, Aya Ghoul, Thomas Küstner iD, Brigitte Gückel, Bernd Kühn, Fritz Schick, Petros Martirosian, Ferdinand Seith

RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 01.10.2025 · 197 (10) · 1176-1187

DOI: 10.1055/a-2480-4885 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, erschienen am 01.10.2025. Verfasst von Cecilia Liang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany. Hauptthemen laut MEDLINE: Kidney, Multiparametric Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Image Interpretation, Computer-Assisted. Die Arbeit nennt 49 Literaturangaben. Gefördert von: Wilhelm Sander-Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiparametric MRI is a promising technique for noninvasive structural and functional imaging of the kidneys that is gaining increasing importance in clinical research. Still, there are no standardized recommendations for analyzing the acquired images and there is a need to further evaluate the accuracy and repeatability of currently recommended MRI parameters. The aim of the study was to evaluate the test-retest repeatability of functional renal MRI parameters using different image analysis strategies. Ten healthy volunteers were examined twice with a multiparametric renal MRI protocol including arterial spin labeling (ASL), diffusion-weighted imaging (DWI) with intravoxel incoherent motion (IVIM), blood-oxygen-dependent (BOLD) imaging, T1 and T2 mapping, and volumetry with an interval of one week. The quantitative results of both kidneys were determined by manual organ segmentation, ROI analysis, and automatic segmentation based on the nnUNet framework. Test-retest repeatability of each parameter was computed using the within-subject coefficient of variance (wCV) and the intraclass coefficient (ICC). Segmentation accuracy and inter-reader agreement were evaluated using the dice score. Structural tissue parameters (T1, T2) showed wCV (%) between 4 and 11 and an ICC between 0.2 and 0.8. Functional parameters (ASL, BOLD and DWI) showed wCV (%) between 3 and 38 and an ICC between 0.0 and 0.7. The highest variances between test-retest scans were observed in perfusion measurements with ASL and IVIM (wCV: 17–37%). Quantitative analysis of the cortex and medulla showed a better repeatability when acquired using manual segmentation compared to ROI-based image analysis. Comparable repeatability was achieved with manual and automatic segmentation of the total kidney. Reasonable repeatability was achieved for all MR parameters. Structural MR parameters showed better repeatability compared to functional parameters. ROI-based image analysis showed overall lower repeatability compared to manual segmentation. Comparable repeatability to manual segmentation as well as acceptable segmentation accuracy could be achieved with automatic segmentation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KidneyMultiparametric Magnetic Resonance ImagingImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedMagnetic Resonance ImagingHumansReproducibility of ResultsAdultMaleFemaleDiffusion Magnetic Resonance ImagingReference ValuesSensitivity and SpecificityMiddle AgedSpin LabelsYoung Adult

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany.
  • Faculty of Medicine, Eberhard Karls University Tübingen, Tübingen, Germany.
  • Medical Image and Data Analysis (MIDAS.lab), Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany.
  • Siemens Healthcare AG, Erlangen, Germany.
  • Section on Experimental Radiology, Departement of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany.

ORCID-Profile: Cecilia Liang, Thomas Küstner

Förderung

  • Wilhelm Sander-Stiftung

Zitieren

APA

Liang, C., Loster, I., Ursprung, S., Ghoul, A., Küstner, T., Gückel, B., Kühn, B., Schick, F., Martirosian, P., & Seith, F. (2025). Multiparametric functional MRI of the kidneys – evaluation of test-retest repeatability and effects of different manual and automatic image analysis strategies. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 197(10), 1176-1187. https://doi.org/10.1055/a-2480-4885

Vancouver

Liang C, Loster I, Ursprung S, Ghoul A, Küstner T, Gückel B, et al. Multiparametric functional MRI of the kidneys – evaluation of test-retest repeatability and effects of different manual and automatic image analysis strategies. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 2025;197(10):1176-1187. doi:10.1055/a-2480-4885

BibTeX
@article{Liang2025,
  author = {Liang, Cecilia and Loster, Isabelle and Ursprung, Stephan and Ghoul, Aya and Küstner, Thomas and Gückel, Brigitte and Kühn, Bernd and Schick, Fritz and Martirosian, Petros and Seith, Ferdinand},
  title = {Multiparametric functional MRI of the kidneys – evaluation of test-retest repeatability and effects of different manual and automatic image analysis strategies},
  journal = {RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren},
  year = {2025},
  volume = {197},
  number = {10},
  pages = {1176--1187},
  doi = {10.1055/a-2480-4885}
}
Kostenlos starten →