EUVIMEDEUVIMED entdecken
Evaluationsstudie

Evaluation of Reproducibility of Measurements of Peripapillary Blood Flow with Laser Speckle Flowgraphy in Healthy and POAG Subjects

Alexander von Vopelius-Feldt, Timothy Hamann iD, Andreas Mayr, Marc Töteberg-Harms

Klinische Monatsblätter für Augenheilkunde · 01.04.2025 · 242 (04) · 384-391

DOI: 10.1055/a-2469-8403 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 01.04.2025. Verfasst von Alexander von Vopelius-Feldt und 3 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology, University Hospital Zurich, Switzerland. Hauptthemen laut MEDLINE: Glaucoma, Open-Angle, Laser-Doppler Flowmetry, Optic Disk, Laser Speckle Contrast Imaging. Die Arbeit nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Peripapillary blood flow is of diagnostic value in glaucoma. Material and Methods We investigated the reproducibility of peripapillary blood flow measurements in healthy individuals and in open-angle glaucoma (OAG) patients with the Nidek laser speckle flowgraphy (LSFG)-NAVI system. Blood flow was calculated as the mean of vascular area (MV), mean of tissue area (MT), and mean of overall flow (MA). Intra-rater, inter-session, and inter-rater reproducibility were assessed by determining the intraclass correlation coefficient (ICC) and coefficient of variance (COV).

Results

There were 28 healthy subjects and 16 patients with OAG who participated in this prospective single-center trial. ICC and COV of intra-rater reproducibility were assessed in MV as 0.901; 6.424, MT as 0.909; 4.025, and MA as 0.965; 4.168. Inter-session reproducibility yielded ICC and COV values of MV (0.834; 9.223), MT (0.904; 6.215), MA (0.909; 7.069). Inter-rater reproducibility was computed for MV as 0.78; 9.758, MT as 0.890; 7.210, and MA as 0.888; 6.942. There was a significant difference in MA (p = 0.0184) between the healthy individuals (mean 36.299) and the OAG group (mean 24.944), which was not observed for MV (p = 0.0735) or MT (p = 0.1351).

Conclusion

High reproducibility of measurements of peripapillary blood flow with the LSFG system was demonstrated in both groups. There is a difference in peripapillary blood flow between healthy controls and OAG patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glaucoma, Open-AngleLaser-Doppler FlowmetryOptic DiskLaser Speckle Contrast ImagingRetinal VesselsHumansReproducibility of ResultsMaleFemaleMiddle AgedBlood Flow VelocitySensitivity and SpecificityAgedReference ValuesAdultRegional Blood FlowObserver VariationProspective Studies

Autor:innen und Institutionen

  • Ophthalmology, University Hospital Zurich, Switzerland.
  • Institute for Medical Biometry and Statistics, Philipps-University-Marburg, Germany.
  • Ophthalmology, Department of Ophthalmology & Visual Sciences, University of Iowa Health Care, Iowa City, IA, United States.

ORCID-Profile: Timothy Hamann

Zitieren

APA

von Vopelius-Feldt, A., Hamann, T., Mayr, A., & Töteberg-Harms, M. (2025). Evaluation of Reproducibility of Measurements of Peripapillary Blood Flow with Laser Speckle Flowgraphy in Healthy and POAG Subjects. Klinische Monatsblätter für Augenheilkunde, 242(04), 384-391. https://doi.org/10.1055/a-2469-8403

Vancouver

von Vopelius-Feldt A, Hamann T, Mayr A, Töteberg-Harms M. Evaluation of Reproducibility of Measurements of Peripapillary Blood Flow with Laser Speckle Flowgraphy in Healthy and POAG Subjects. Klinische Monatsblätter für Augenheilkunde. 2025;242(04):384-391. doi:10.1055/a-2469-8403

BibTeX
@article{vonVopeliusFeldt2025,
  author = {von Vopelius-Feldt, Alexander and Hamann, Timothy and Mayr, Andreas and Töteberg-Harms, Marc},
  title = {Evaluation of Reproducibility of Measurements of Peripapillary Blood Flow with Laser Speckle Flowgraphy in Healthy and POAG Subjects},
  journal = {Klinische Monatsblätter für Augenheilkunde},
  year = {2025},
  volume = {242},
  number = {04},
  pages = {384--391},
  doi = {10.1055/a-2469-8403}
}
Kostenlos starten →