Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 01.08.2025 · 197 (08) · 913-925
DOI: 10.1055/a-2462-2419 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, erschienen am 01.08.2025. Verfasst von Anna Schildt und 9 weiteren Autor:innen. Beteiligte Einrichtung: Core Facility Multimodal Small Animal Imaging, Rostock University Medical Center, Rostock, Germany. Hauptthemen laut MEDLINE: Radiation Protection, Positron Emission Tomography Computed Tomography, Multimodal Imaging, Radiometry. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
Clinical imaging techniques such as positron emission tomography (PET) in combination with computed tomography (CT) are increasingly being used in biomedical research involving small animal models. The handling of open radioactive substances (radiopharmaceuticals) necessary for PET imaging requires prior official authorization for handling, the application of radiation protection principles, and regular training. The overriding aim of radiation protection is to protect the personnel directly involved, other persons, and the environment from the harmful effects of ionizing radiation. This paper aims to provide an overview of the regulatory requirements of the Radiation Protection Act (StrlSchG), the Radiation Protection Ordinance (StrlSchV), and the associated standards and guidelines. Furthermore, their implementation in practical work in small animal imaging using PET/CT is shown. We will focus on the individual steps of the imaging process, from delivery of the radiopharmaceuticals to waste disposal. This should provide interested researchers with an initial overview of the safe and successful use of the method. In addition, exposure values from the last six years in the literature were analyzed. While personal dosimetric monitoring in clinical PET/CT imaging has been extensively published, there is no published data known to us for personnel for PET/CT research with small animals. The evaluation of the personal dosimetric monitoring of our small animal imaging facility with 7 employees over 4 years revealed an increased personal and finger dose normalized to the injected activity and compared to human PET/CT imaging. Nevertheless, the annual personal dose or annual finger dose in small animal imaging (Hp(10): 1.7 mSv, Hp(0.07): 64 mSv) is lower than for personnel performing human PET/CT imaging at the local University Department of Nuclear Medicine (Hp(10): 3.8 mSv, Hp(0.07): 156 mSv) or published values, and is well below the legally permissible maximum dose of 20 or 500 mSv per year. The increasing use of PET/CT in small animal research can be safely utilized if the radiation protection principles are implemented and continuously trained.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Core Facility Multimodal Small Animal Imaging, Rostock University Medical Center, Rostock, Germany.
- Radiation Protection Office, Rostock University Medical Center, Rostock, Germany.
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
- Department of Nuclear Medicine, Rostock University Medical Center, Rostock, Germany.
- Rudolf-Zenker-Institute for Experimental Surgery, Rostock University Medical Center, Rostock, Germany.
ORCID-Profile: Anna Schildt, Marc-André Weber, Tobias Lindner
Zitieren
APA
Schildt, A., Sänger, P., Lütgens, M., Polei, S., Lappe, C., Joksch, M., Krause, B. J., Vollmar, B., Weber, M. A., & Lindner, T. (2025). Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 197(08), 913-925. https://doi.org/10.1055/a-2462-2419
Vancouver
Schildt A, Sänger P, Lütgens M, Polei S, Lappe C, Joksch M, et al. Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 2025;197(08):913-925. doi:10.1055/a-2462-2419
BibTeX
@article{Schildt2025,
author = {Schildt, Anna and Sänger, Peter and Lütgens, Matthias and Polei, Stefan and Lappe, Chris and Joksch, Markus and Krause, Bernd Joachim and Vollmar, Brigitte and Weber, Marc-André and Lindner, Tobias},
title = {Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging},
journal = {RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren},
year = {2025},
volume = {197},
number = {08},
pages = {913--925},
doi = {10.1055/a-2462-2419}
}
EUVIMED