EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of 2D and 3D lung lobe quantification with Ventilation/Perfusion Ratio

Julia Katharina Vogt, Wolfgang Kurt Vogt, Alexander Heinzel, Felix M Mottaghy

Nuklearmedizin - NuclearMedicine · 01.04.2025 · 64 (02) · 142-149

DOI: 10.1055/a-2460-7254 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2025. Verfasst von Julia Katharina Vogt und 3 weiteren Autor:innen. Beteiligte Einrichtung: GB Sicherheit & Compliance, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Lung, Ventilation-Perfusion Ratio, Pulmonary Embolism. Die Arbeit nennt 29 Literaturangaben. Gefördert von: GE Healthcare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, standard 2D lung lobe quantification is compared with two 3D lung lobe quantification software tools to investigate the clinical benefit of a 3D approach. The accuracy of 2D versus 3D lung lobe quantification is evaluated based on the calculated numerical ventilation-perfusion ratio (VQR) using a receiver operating curve (ROC) analysis. A study group of 50 consecutive patients underwent a planar lung scintigraphy (anterior/posterior) as well as ventilation/perfusion single photon emission computed tomography (SPECT/CT) to exclude acute pulmonary embolism. All data were acquired with SPECT OPTIMA NM/CT 640 (GE Healthcare). 2D analysis was performed for all ventilation/perfusion scans using a lung analysis tool (Syngo Workstation, Siemens Healthineers). 3D quantification analysis was performed using QLUNG (Q. Lung, Xeleris 4.0, GE Healthcare) and LLQ (Hermes Hybrid 3D Lung Lobar Quantification, Hermes Medical Solutions). The area under the ROC curve (AUC) served as a decision criterion to find the best agreement between clinical PE findings and calculated PE candidates of the 2D and 3D methods. The significance of the ROC curves was evaluated using the DeLong comparison. A significant difference between 2D/3D could be determined. Both 3D approaches showed robust and comparable results. The AUC range of [0.10, 0.67] was given for 2D lobar analysis, QLUNG AUC range revealed in [0.39,0.74] and LLQ AUC range was [0.42,0.72]. Averaged over all lung lobes an AUC=0.39 was given for 2D analysis and AUC=0.58 was given for LLQ/QLUNG. We could demonstrate the better performance of 3D analysis compared to 2D analysis. Consequently, is recommended to use a 3D approach in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalLungVentilation-Perfusion RatioPulmonary EmbolismVentilation-Perfusion ScanSingle Photon Emission Computed Tomography Computed TomographyHumansMaleFemaleMiddle AgedAgedReproducibility of ResultsSensitivity and SpecificityAdultTomography, Emission-Computed, Single-Photon

Autor:innen und Institutionen

  • GB Sicherheit & Compliance, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Klinik für Nuklearmedizin, University Hospital Aachen, Aachen, Germany.
  • Faculty of Electrical Engineering & Information Technology, University of Applied Sciences, Düsseldorf, Germany.
  • Max-Planck-Institut für Eisenforschung GmbH, Düsseldorf, Germany.
  • Nuclear Medicine, University Hospital Halle, Halle/Saale, Germany.
  • Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany.

Förderung

  • GE Healthcare

Zitieren

APA

Vogt, J. K., Vogt, W. K., Heinzel, A., & Mottaghy, F. M. (2025). Comparison of 2D and 3D lung lobe quantification with Ventilation/Perfusion Ratio. Nuklearmedizin - NuclearMedicine, 64(02), 142-149. https://doi.org/10.1055/a-2460-7254

Vancouver

Vogt JK, Vogt WK, Heinzel A, Mottaghy FM. Comparison of 2D and 3D lung lobe quantification with Ventilation/Perfusion Ratio. Nuklearmedizin - NuclearMedicine. 2025;64(02):142-149. doi:10.1055/a-2460-7254

BibTeX
@article{Vogt2025,
  author = {Vogt, Julia Katharina and Vogt, Wolfgang Kurt and Heinzel, Alexander and Mottaghy, Felix M},
  title = {Comparison of 2D and 3D lung lobe quantification with Ventilation/Perfusion Ratio},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2025},
  volume = {64},
  number = {02},
  pages = {142--149},
  doi = {10.1055/a-2460-7254}
}
Kostenlos starten →