EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Further Validating the Robotic Microsurgery Platform through Preclinical Studies on Rat Femoral Artery and Vein

Jeongmok Cho, Donggeon Kim, Taehyun Kim, Changsik John Pak, Hyunsuk Peter Suh, Joon Pio Hong iD

Journal of Reconstructive Microsurgery · 01.09.2025 · 41 (07) · 595-605

DOI: 10.1055/a-2460-4940 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.09.2025. Verfasst von Jeongmok Cho und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, University of Ulsan, College of Medicine, Seoul Asan Medical Center, Seoul, Korea. Hauptthemen laut MEDLINE: Microsurgery, Robotic Surgical Procedures, Femoral Artery, Femoral Vein. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MMI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research aims to validate the proficiency and accuracy of the robotic microsurgery platform using rat femoral vessel model. A total of 256 rat femoral vessels were performed, half using robotic and the other by manual microanastomosis by eight microsurgeons with less than 5 years of experience given eight trials (rats) each. Vessel demographics, proficiency (duration of suture and Structured Assessment of Robotic Microsurgical Skills [SARMS]), and accuracy (patency and scanning electron microscopic [SEM]) were analyzed between the two groups. Using the robot, an average of four trials was needed to reach a plateau in total anastomosis time and patency. Significant more time was required for each vessel anastomosis (34.33 vs. 21.63 minutes on the eighth trial, p < 0.001) one factor being a higher number of sutures compared with the handsewn group (artery: 7.86 ± 0.51 vs. 5.86 ± 0.67, p = 0.035, vein: 12.63 ± 0.49 vs. 9.57 ± 0.99, p = 0.055). The SARMS scores became nonsignificant between the two groups on the fourth trial. The SEM showed a higher tendency of unevenly spaced sutures, infolding, and tears in the vessel wall for the handsewn group. Using the robot, similar patency, accuracy, and proficiency can be reached through a fast but steep learning process within four trials (anastomosis of eight vessels) as the handsewn group. The robotic anastomosis may take longer time, but this is due to the increased number of sutures reflecting higher precision and accuracy. Further insight of precision and accuracy was found through the SEM demonstrating the possibility of the robot to prevent unexpected and unwanted complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrosurgeryRobotic Surgical ProceduresFemoral ArteryFemoral VeinVascular Surgical ProceduresAnimalsRatsAnastomosis, SurgicalVascular PatencyModels, AnimalMale

Autor:innen und Institutionen

  • Department of Plastic and Reconstructive Surgery, University of Ulsan, College of Medicine, Seoul Asan Medical Center, Seoul, Korea.

ORCID-Profile: Joon Pio Hong

Förderung

  • MMI

Zitieren

APA

Cho, J., Kim, D., Kim, T., Pak, C. J., Suh, H. P., & Hong, J. P. (2025). Further Validating the Robotic Microsurgery Platform through Preclinical Studies on Rat Femoral Artery and Vein. Journal of Reconstructive Microsurgery, 41(07), 595-605. https://doi.org/10.1055/a-2460-4940

Vancouver

Cho J, Kim D, Kim T, Pak CJ, Suh HP, Hong JP. Further Validating the Robotic Microsurgery Platform through Preclinical Studies on Rat Femoral Artery and Vein. Journal of Reconstructive Microsurgery. 2025;41(07):595-605. doi:10.1055/a-2460-4940

BibTeX
@article{Cho2025,
  author = {Cho, Jeongmok and Kim, Donggeon and Kim, Taehyun and Pak, Changsik John and Suh, Hyunsuk Peter and Hong, Joon Pio},
  title = {Further Validating the Robotic Microsurgery Platform through Preclinical Studies on Rat Femoral Artery and Vein},
  journal = {Journal of Reconstructive Microsurgery},
  year = {2025},
  volume = {41},
  number = {07},
  pages = {595--605},
  doi = {10.1055/a-2460-4940}
}