EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Collection and Application of Autologous Amniotic Fluid to Cesarean Delivery Closure

Chad A Grotegut, Kristin E Weaver, Lena Fried, Sarah K Dotters-Katz, Jennifer B Gilner

American Journal of Perinatology Reports · 01.07.2024 · 14 (04) · e262-e269

DOI: 10.1055/a-2445-7954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Perinatology Reports, erschienen am 01.07.2024. Verfasst von Chad A Grotegut und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Maternal-Fetal Medicine, Department of Obstetrics and GynecologyDuke University, Durham, North Carolina. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Recibio, Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Amniotic fluid and amnion membranes have been used in surgery specialties to improve wound healing and decrease surgical adhesion formation.

Objective

The objective was to determine if amniotic fluid could be collected at cesarean delivery and then reapplied to the layers of the closure using the CeaLogic Specimen Collection and Ratio Applicator Kit. Study Design Twenty pregnant individuals who met inclusion and exclusion criteria were enrolled. Amniotic fluid was collected at artificial rupture of the membranes using the collection kit. Autologous amniotic fluid was then transferred to the applicator kit, mixed with calcium chloride solution, and applied directly to each of the surgical repair layers during closure: closed hysterotomy incision, closed fascial incision, closed subcutaneous layer (if applicable), and closed skin. Subjects were then followed for six weeks. Photographs of the incision were taken immediately following surgery, one-week following surgery, and at the four-week postpartum visit. The Modified Hollander Cosmesis Score was used to assess wound appearance.

Results

Twenty pregnant individuals who met inclusion and exclusion criteria were enrolled and all completed the study. The mean volume of amniotic fluid collected was 30 ± 19 mL. The median (IQR) Modified Hollander Cosmesis Score (Range 0-best, to 6-worst) at the one week and four-week postpartum visits was 0 (0,1) and 0 (0,2), respectively. There were no wound complications nor surgical site infections among the cohort. Further, there were no unscheduled visits for wound issues among any of the subjects.

Conclusion

The CeaLogic Specimen Collection and Ratio Applicator Kits can be used to collect and reapply autologous amniotic fluid at the time of cesarean delivery. Future studies are needed to determine if the application of autologous amniotic fluid to cesarean delivery closure can improve cosmesis and wound healing, as well as decrease the risk for the development of intraabdominal adhesions.

Schlagwörter

Stichwörter der Autor:innen

allograftamniotic fluidautologouscesarean deliverypostsurgical adhesionsscar tissuesurgical site infectionwound complicationswound cosmesiswound infection

Autor:innen und Institutionen

  • Division of Maternal-Fetal Medicine, Department of Obstetrics and GynecologyDuke University, Durham, North Carolina.

Förderung

  • Recibio, Inc

Zitieren

APA

Grotegut, C. A., Weaver, K. E., Fried, L., Dotters-Katz, S. K., & Gilner, J. B. (2024). The Collection and Application of Autologous Amniotic Fluid to Cesarean Delivery Closure. American Journal of Perinatology Reports, 14(04), e262-e269. https://doi.org/10.1055/a-2445-7954

Vancouver

Grotegut CA, Weaver KE, Fried L, Dotters-Katz SK, Gilner JB. The Collection and Application of Autologous Amniotic Fluid to Cesarean Delivery Closure. American Journal of Perinatology Reports. 2024;14(04):e262-e269. doi:10.1055/a-2445-7954

BibTeX
@article{Grotegut2024,
  author = {Grotegut, Chad A and Weaver, Kristin E and Fried, Lena and Dotters-Katz, Sarah K and Gilner, Jennifer B},
  title = {The Collection and Application of Autologous Amniotic Fluid to Cesarean Delivery Closure},
  journal = {American Journal of Perinatology Reports},
  year = {2024},
  volume = {14},
  number = {04},
  pages = {e262--e269},
  doi = {10.1055/a-2445-7954}
}
Kostenlos starten →