EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Successful guidewire navigation technique in the bile duct using a 3F microcatheter and balloon wedge

Shota Harai, Dai Yoshimura, Naoto Imagawa, Natsuhiko Kuratomi, Satoshi Kawakami, Shinichi Takano iD

Endoscopy International Open · 13.01.2025 · 13 (CP)

DOI: 10.1055/a-2441-8632 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 13.01.2025. Verfasst von Shota Harai und 5 weiteren Autor:innen. Beteiligte Einrichtung: First Department of Internal Medicine, University of Yamanashi Faculty of Medicine Graduate School of Medicine, Chuo, Japan. Die Arbeit nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An 80-year-old man presented with hilar cholangiocarcinoma, Bismuth type II ([ Fig. 1 ]), and biliary drainage of plastic stents ([ Fig. 2 ]). Recurrent biliary obstruction (RBO) occurred every month for six months. Due to its frequency, we inserted an uncovered self-expandable metallic stent (USEMS). Fig. 1 Image findings before biliary drainage. a Coronal view of the computed tomography scan showing wall thickening with a contrasting effect in the hilar bile ducts. b Magnetic resonance computed tomography showing Bismuth type II. Fig. 2 First endoscopic retrograde cholangiopancreatography. a Cholangiography showing the limited connection between the left and right hepatic ducts. The anterior and posterior branches are connected. b Placement of plastic stents into B3 and B8. We assumed that primary disease progression would result in Bismuth type IIIa necessitating drainage in three areas: anterior, posterior, and left lobes. Triple metal stenting could complicate reintervention; therefore, our plan was to conduct an endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) on B3 and insert a USEMS in the anterior and posterior branches with a stent-in-stent. We performed endoscopic retrograde cholangiopancreatography using the TJF290 duodenoscope (Olympus, Japan). Cholangiography showed that the confluence of the posterior branch was steep, making guidewire (GW) navigation difficult. Therefore, the anterior branch was wedged with a balloon 7F catheter (Zeon medical, Japan) and a 3F microcatheter (Hanako Medical, Japan) was delivered alongside it ([ Video 1 ]). The balloon wedge allowed the leading force of the GW to pass and be placed in the posterior branch. Furthermore, the 3F microcatheter could be inserted beyond the bile duct bend, facilitating deep insertion of the GW after cholangiography ([ Fig. 3 ]). Finally, the USEMS was successfully placed with a stent-in stent technique and the patient went about 6 months without RBO. The multi-lumen balloon catheter [ 1 ] or rendezvous technique with EUS-hepaticoduodenostomy [ 2 ] may be useful for a steep angle at the confluence of the posterior branch; however, in the former, the GW lumen is fixed, which may reduce the flexibility of bile duct selection. Deep placement of the 3F microcatheter into the bile duct for cholangiography enabled GW insertion into the precise site. The usefulness of a 3F microcatheter has been reported [ 3 ]. We report this procedure with the aim of contributing to successful drainage of hilar biliary stenoses. Quality: mobile 360 480 720 Download Successful guidewire navigation technique in the bile duct using a 3F microcatheter and balloon wedge.Video 1 Fig. 3 Guidewire seeking technique in the bile duct with a 3F microcatheter and balloon wedge. a Selection of the posterior branch by only the guidewire (GW) is difficult. b The 3-F microcatheter passes easily alongside the balloon catheter and biliary cannulation. c,d The balloon wedge of the anterior branch allows the GW into the posterior branch. e,f The GW follows the 3F microcatheter, is placed into the posterior branch, and cholangiography is performed. g The stent-in stent method deploys the uncovered self-expandable metallic stent. Publication History Received: 29 July 2024 Accepted after revision: 10 October 2024 Article published online: 13 January 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany Bibliographical Record Shota Harai, Dai Yoshimura, Naoto Imagawa, Natsuhiko Kuratomi, Satoshi Kawakami, Shinichi Takano. Successful guidewire navigation technique in the bile duct using a 3F microcatheter and balloon wedge. Endosc Int Open 2025; 13: a24418632. DOI: 10.1055/a-2441-8632

Autor:innen und Institutionen

  • First Department of Internal Medicine, University of Yamanashi Faculty of Medicine Graduate School of Medicine, Chuo, Japan.

ORCID-Profile: Shinichi Takano

Zitieren

APA

Harai, S., Yoshimura, D., Imagawa, N., Kuratomi, N., Kawakami, S., & Takano, S. (2025). Successful guidewire navigation technique in the bile duct using a 3F microcatheter and balloon wedge. Endoscopy International Open, 13(CP). https://doi.org/10.1055/a-2441-8632

Vancouver

Harai S, Yoshimura D, Imagawa N, Kuratomi N, Kawakami S, Takano S. Successful guidewire navigation technique in the bile duct using a 3F microcatheter and balloon wedge. Endoscopy International Open. 2025;13(CP). doi:10.1055/a-2441-8632

BibTeX
@article{Harai2025,
  author = {Harai, Shota and Yoshimura, Dai and Imagawa, Naoto and Kuratomi, Natsuhiko and Kawakami, Satoshi and Takano, Shinichi},
  title = {Successful guidewire navigation technique in the bile duct using a 3F microcatheter and balloon wedge},
  journal = {Endoscopy International Open},
  year = {2025},
  volume = {13},
  number = {CP},
  doi = {10.1055/a-2441-8632}
}
Kostenlos starten →