Electrophysiological Signal Validation of Regenerative Peripheral Nerve Interface at Nerve Ending: A Preliminary Rat Model Experiment
Journal of Reconstructive Microsurgery · 01.07.2025 · 41 (06) · 478-488
DOI: 10.1055/a-2434-4605 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.07.2025. Verfasst von Jeongmok Cho und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea. Hauptthemen laut MEDLINE: Nerve Regeneration, Neural Conduction, Peroneal Nerve, Peripheral Nerve Injuries. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Background
As the number of extremity amputations continues to rise, so does the demand for prosthetics. Emphasizing the importance of a nerve interface that effectively amplifies and transmits physiological signals through peripheral nerve surgery is crucial for achieving intuitive control. The regenerative peripheral nerve interface (RPNI) is recognized for its potential to provide this technical support. Through animal experiment, we aimed to confirm the actual occurrence of signal amplification.
Methods
Rats were divided into three experimental groups: control, common peroneal nerve transection, and RPNI. Nerve surgeries were performed for each group, and electromyography (EMG) and nerve conduction studies (NCS) were conducted at the initial surgery, as well as at 2, 4, and 8 weeks postoperatively.
Results
All implemented RPNIs exhibited viability and displayed adequate vascularity with the proper color. Clear differences in latency and amplitude were observed before and after 8 weeks of surgery in all groups (p < 0.05). Notably, the RPNI group demonstrated a significantly increased amplitude compared with the control group after 8 weeks (p = 0.031). Latency increased in all groups 8 weeks after surgery. The RPNI group exhibited relatively clear signs of denervation with abnormal spontaneous activities (ASAs) during EMG.
Conclusion
This study is one of few preclinical studies that demonstrate the electrophysiological effects of RPNI and validate the neural signals. It serves as a foundational step for future research in human–machine interaction and nerve interfaces.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.
ORCID-Profile: Joon Pio Hong
Zitieren
APA
Cho, J., Suh, H. P., Pak, C., & Hong, J. P. (2025). Electrophysiological Signal Validation of Regenerative Peripheral Nerve Interface at Nerve Ending: A Preliminary Rat Model Experiment. Journal of Reconstructive Microsurgery, 41(06), 478-488. https://doi.org/10.1055/a-2434-4605
Vancouver
Cho J, Suh HP, Pak C, Hong JP. Electrophysiological Signal Validation of Regenerative Peripheral Nerve Interface at Nerve Ending: A Preliminary Rat Model Experiment. Journal of Reconstructive Microsurgery. 2025;41(06):478-488. doi:10.1055/a-2434-4605
BibTeX
@article{Cho2025,
author = {Cho, Jeongmok and Suh, Hyunsuk Peter and Pak, Changsik and Hong, Joon Pio},
title = {Electrophysiological Signal Validation of Regenerative Peripheral Nerve Interface at Nerve Ending: A Preliminary Rat Model Experiment},
journal = {Journal of Reconstructive Microsurgery},
year = {2025},
volume = {41},
number = {06},
pages = {478--488},
doi = {10.1055/a-2434-4605}
}