EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Initial experience with transmural use of a new endoscopic ultrasound electric core needle biopsy device: Case series

Antonio Mendoza Ladd iD, Amer Alsamman, Karleen Meiklejohn, Omar Viramontes

Endoscopy International Open · 01.10.2024 · 12 (10) · E1237-E1241

DOI: 10.1055/a-2427-2311 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 01.10.2024. Verfasst von Antonio Mendoza Ladd und 3 weiteren Autor:innen. Beteiligte Einrichtung: Internal Medicine/Gastroenterology, UC Davis Medical Center, Sacramento, United States. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and study aims Endoscopic ultrasound-guided biopsy via fine-needle biopsy/fine-needle aspiration (FNB/FNA) is currently the standard method to sample tumors in the mediastinum and abdomen. Although specimens obtained with these needles are acceptable, a histological diagnosis is not always possible. Recently, a new EUS-guided core needle biopsy (EUS-CNB) device became available. Herein, we describe the first experience with its use in a transmural fashion. Patients and methods This was a case series of patients who underwent EUS-CNB at an academic center. All patients provided written informed consent and were observed in the hospital ≥ 48 hours after the procedure.

Results

A total of 8 patients underwent EUSC-CNB: five in the pancreas, two in the retroperitoneum, and one in the mediastinum. The diagnostic accuracy of EUS-CNB was 100% after one actuation. In four patients, same-session FNB and EUS-CNB were obtained from the same lesion with superior tissue sample in the latter. No adverse events were documented.

Conclusions

To our knowledge this is the first report on transmural use of EUS-CNB in gastroenterology. Our findings suggest that the device is effective and safe. Larger studies comparing it with FNA/FNB needles will be required to further assess performance and safety.

Schlagwörter

Stichwörter der Autor:innen

Endoscopic ultrasonographyEndoscopy Upper GI TractFine-needle aspiration/biopsyPancreasPrecancerous conditions & cancerous lesions (displasia and cancer) stomachTissue diagnosis

Autor:innen und Institutionen

  • Internal Medicine/Gastroenterology, UC Davis Medical Center, Sacramento, United States.

ORCID-Profile: Antonio Mendoza Ladd

Zitieren

APA

Mendoza Ladd, A., Alsamman, A., Meiklejohn, K., & Viramontes, O. (2024). Initial experience with transmural use of a new endoscopic ultrasound electric core needle biopsy device: Case series. Endoscopy International Open, 12(10), E1237-E1241. https://doi.org/10.1055/a-2427-2311

Vancouver

Mendoza Ladd A, Alsamman A, Meiklejohn K, Viramontes O. Initial experience with transmural use of a new endoscopic ultrasound electric core needle biopsy device: Case series. Endoscopy International Open. 2024;12(10):E1237-E1241. doi:10.1055/a-2427-2311

BibTeX
@article{MendozaLadd2024,
  author = {Mendoza Ladd, Antonio and Alsamman, Amer and Meiklejohn, Karleen and Viramontes, Omar},
  title = {Initial experience with transmural use of a new endoscopic ultrasound electric core needle biopsy device: Case series},
  journal = {Endoscopy International Open},
  year = {2024},
  volume = {12},
  number = {10},
  pages = {E1237--E1241},
  doi = {10.1055/a-2427-2311}
}
Kostenlos starten →