EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Portal vein velocity and its dynamics: a potentially useful tool for detecting clinically silent transjugular intrahepatic porto-systemic shunt dysfunction using Doppler ultrasonography

Rareș Crăciun iD, Horia Ștefănescu iD, Oana Nicoară-Farcău, Petra Fischer, Andreea Fodor, Marcel Tanţău, Corina Radu, Zeno Spârchez, Bogdan Procopeţ

Ultrasound International Open · 17.12.2024 · 10 (CP)

DOI: 10.1055/a-2422-8339 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasound International Open, erschienen am 17.12.2024. Verfasst von Rareș Crăciun und 8 weiteren Autor:innen. Beteiligte Einrichtung: Internal Medicine Department, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministerul Cercetării şi Inovării.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ultrasound (US) surveillance for transjugular intrahepatic portosystemic shunt (TIPS) dysfunction has yet to be standardized, as clear-cut criteria have not been conventionally defined. This study evaluated the role of US-based parameters in detecting hemodynamic TIPS dysfunction (HD).

Methods

We included consecutive patients treated with TIPS. All patients were scheduled within the first six weeks after the procedure for TIPS revision, comprised of a Doppler US exam and invasive hemodynamic reassessment. Clinical TIPS dysfunction (CD) was defined as symptom recurrence, while HD was defined by a portal pressure gradient (PPG)≥12 mmHg. The predictive capabilities of Doppler US for predicting TIPS dysfunction were tested against the hemodynamic gold standard.

Results

86 patients were included. Secondary prophylaxis of variceal bleeding was the main indication for TIPS in 72 patients (83.7%), while 27 (31.4%) had refractory ascites. HD occurred in 37 cases (43%), of which 25 patients (67.5%) had no CD. Patients with HD had a significantly lower portal vein velocity (PVV): 35 (20–45) cm/s vs. 40.5 (35–50) cm/s, p=0.02. Compared to the immediate post-TIPS assessment, the patients without HD had a ΔPVV of 6.08±19.8 cm/s vs. a decrease of − 8.2±20.2 cm/s in HD (p=0.04). Using a cut-off value of 40.5 cm/s, PVV had an AUROC of 0.705 for predicting HD, while the addition of ΔPVV (cut-off 9.5 cm/s) improved the AUROC to 0.78.

Conclusion

Despite adequate symptom control, a considerable percentage of patients have a post-TIPS PPG≥12 mmHg. The dynamic assessment of PVV and its temporal dynamics can reliably predict TIPS dysfunction.

Schlagwörter

Stichwörter der Autor:innen

Color Doppler ultrasoundTIPSinterventional proceduresshuntstransjugular intrahepatic porto-systemic shunt

Autor:innen und Institutionen

  • Internal Medicine Department, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
  • Gastroenterology Department, Prof. Dr. O. Fodor Regional Institute of Gastroenterology and Hepatology, Cluj-Napoca, Romania.
  • CESTER, Technical University of Cluj-Napoca, Cluj-Napoca, Romania.

ORCID-Profile: Rareș Crăciun, Horia Ștefănescu

Förderung

  • Ministerul Cercetării şi Inovării

Zitieren

APA

Crăciun, R., Ștefănescu, H., Nicoară-Farcău, O., Fischer, P., Fodor, A., Tanţău, M., Radu, C., Spârchez, Z., & Procopeţ, B. (2024). Portal vein velocity and its dynamics: a potentially useful tool for detecting clinically silent transjugular intrahepatic porto-systemic shunt dysfunction using Doppler ultrasonography. Ultrasound International Open, 10(CP). https://doi.org/10.1055/a-2422-8339

Vancouver

Crăciun R, Ștefănescu H, Nicoară-Farcău O, Fischer P, Fodor A, Tanţău M, et al. Portal vein velocity and its dynamics: a potentially useful tool for detecting clinically silent transjugular intrahepatic porto-systemic shunt dysfunction using Doppler ultrasonography. Ultrasound International Open. 2024;10(CP). doi:10.1055/a-2422-8339

BibTeX
@article{Crciun2024,
  author = {Crăciun, Rareș and Ștefănescu, Horia and Nicoară-Farcău, Oana and Fischer, Petra and Fodor, Andreea and Tanţău, Marcel and Radu, Corina and Spârchez, Zeno and Procopeţ, Bogdan},
  title = {Portal vein velocity and its dynamics: a potentially useful tool for detecting clinically silent transjugular intrahepatic porto-systemic shunt dysfunction using Doppler ultrasonography},
  journal = {Ultrasound International Open},
  year = {2024},
  volume = {10},
  number = {CP},
  doi = {10.1055/a-2422-8339}
}
Kostenlos starten →