Feasibility of newly designed rotatable sphincterotome for endoscopic sphincterotomy (with video)
Endoscopy International Open · 01.11.2024 · 12 (11) · E1374-E1378
DOI: 10.1055/a-2422-2425 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 01.11.2024. Verfasst von Yasuki Hori und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences and Medical School, Nagoya, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background and study aims Endoscopic sphincterotomy can be challenging especially in patients with surgically altered anatomy. Although a rotatable sphincterotome (r-sphincterotome) may be useful, its rotational function is often inadequate. We evaluated the feasibility of a newly designed r-sphincterotome equipped with a well-conceived cutting wire.
Methods
We measured the movement and dynamics of both the newly designed r-sphincterotome and two existing r-sphincterotomes using in-house equipment. Ideally, the rotational force exerted at the proximal end should transmit directly to the distal end. But it is often challenging, particularly within the constraints of a bent endoscope and working channel. We collected data regarding deviation from the ideal value 10 times for each sphincterotome.
Results
The deviation from the ideal value was significantly lower with the newly designed r-sphincterotome than with the conventional r-sphincterotomes (44.9 ± 27.8 vs. 73.7 ± 44.6 and 130.1 ± 71.4 degrees, respectively; P < 0.001). The newly designed r-sphincterotome rotated smoothly and consistently at a constant speed, mirroring the input rotation.
Conclusions
We evaluated the feasibility of the newly designed r-sphincterotome using an experimental model. We believe that the findings from these experiments may contribute to easier and more precise sphincterotomies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences and Medical School, Nagoya, Japan.
- Department of Gastroenterology and Metabolism, Nagoya City University East Medical Center, Nagoya, Japan.
- Department of Gastroenterology, Gifu Prefectural Tajimi Hospital, Tajimi, Japan.
- Department of Gastroenterology, Toyokawa Municipal Hospital, Toyokawa, Japan.
- Department of Gastroenterology, Japanese Red Cross Aichi Medical Center Nagoya Daini Hospital, Nagoya, Japan.
- Department of Gastroenterology, Nagoya City University West Medical Center, Nagoya, Japan.
ORCID-Profile: Yasuki Hori, Itaru Naitoh, Michihiro Yoshida, Akihisa Kato
Zitieren
APA
Hori, Y., Hayashi, K., Naitoh, I., Okumura, F., Anbe, K., Miyabe, K., Hirano, A., Takada, H., Jinno, N., Yoshida, M., Kato, A., Kachi, K., Sahashi, H., Adachi, A., Toyohara, T., Kuno, K., Kito, Y., & Kataoka, H. (2024). Feasibility of newly designed rotatable sphincterotome for endoscopic sphincterotomy (with video). Endoscopy International Open, 12(11), E1374-E1378. https://doi.org/10.1055/a-2422-2425
Vancouver
Hori Y, Hayashi K, Naitoh I, Okumura F, Anbe K, Miyabe K, et al. Feasibility of newly designed rotatable sphincterotome for endoscopic sphincterotomy (with video). Endoscopy International Open. 2024;12(11):E1374-E1378. doi:10.1055/a-2422-2425
BibTeX
@article{Hori2024,
author = {Hori, Yasuki and Hayashi, Kazuki and Naitoh, Itaru and Okumura, Fumihiro and Anbe, Kaiki and Miyabe, Katsuyuki and Hirano, Atsuyuki and Takada, Hiroki and Jinno, Naruomi and Yoshida, Michihiro and Kato, Akihisa and Kachi, Kenta and Sahashi, Hidenori and Adachi, Akihisa and Toyohara, Tadashi and Kuno, Kayoko and Kito, Yusuke and Kataoka, Hiromi},
title = {Feasibility of newly designed rotatable sphincterotome for endoscopic sphincterotomy (with video)},
journal = {Endoscopy International Open},
year = {2024},
volume = {12},
number = {11},
pages = {E1374--E1378},
doi = {10.1055/a-2422-2425}
}
EUVIMED