Fachartikel in der Zeitschrift American Journal of Perinatology, erschienen am 01.04.2025. Verfasst von Hannah Hoff und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Baylor College of Medicine, Houston, Texas. Hauptthemen laut MEDLINE: Algorithms, Heart Defects, Congenital, Neonatal Screening. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
In 2018, an expert panel recommended two key modifications to the most used algorithm for screening neonates for critical congenital heart disease (CCHD). Our aim was to evaluate the outcomes of the modified algorithm compared with those of the original algorithm in a real-world setting. We compared the performance characteristics of an original CCHD algorithm used to screen term neonates at a large hospital system between October 26, 2018, and October 15, 2020, and the recommended modified algorithm used between October 15, 2020, and June 30, 2022. We calculated sensitivity, specificity, false positive rate, proportion of false positives with non-CCHD illness, and error rates of test administration and interpretation for each algorithm. Sensitivity was not significantly different between the modified algorithm compared with the original algorithm (40.00 vs. 12.50%, p ≥0.99), but specificity was lower (and hence false positive rate was higher) in the modified algorithm (99.91 vs. 99.98%, p < 0.001). Despite a higher false positive rate in the modified algorithm, the proportion of false positives with significant non-CCHD illness was similar (36.47 vs. 28.57%, p ≥0.99), a finding that translated to an increase in the number of cases of significant non-CCHD illness detected (11 cases out of 32,178 screens vs. 2 cases out of 32,984 screens). Error rates of test administration and interpretation were similar between the two algorithms. In this limited study, the modified algorithm for CCHD screening using pulse oximetry had a higher false positive rate than that of the original American Academy of Pediatrics algorithm. However, this higher rate led to an increased overall number of cases detected of significant non-CCHD illness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Internal Medicine, Baylor College of Medicine, Houston, Texas.
- Department of Pediatrics, Northside Hospital, Atlanta, Georgia.
- Department of Pediatrics, Emory University School of Medicine, Atlanta, Georgia.
- Department of Cardiology, Children's Healthcare of Atlanta, Atlanta, Georgia.
ORCID-Profile: Matthew E Oster
Zitieren
APA
Hoff, H., Quary, S., Keesari, R., & Oster, M. E. (2025). Evaluating the Modified American Academy of Pediatrics Screening Algorithm for Critical Congenital Heart Disease. American Journal of Perinatology, 42(05), 674-682. https://doi.org/10.1055/a-2416-5637
Vancouver
Hoff H, Quary S, Keesari R, Oster ME. Evaluating the Modified American Academy of Pediatrics Screening Algorithm for Critical Congenital Heart Disease. American Journal of Perinatology. 2025;42(05):674-682. doi:10.1055/a-2416-5637
BibTeX
@article{Hoff2025,
author = {Hoff, Hannah and Quary, Sharon and Keesari, Rohali and Oster, Matthew E},
title = {Evaluating the Modified American Academy of Pediatrics Screening Algorithm for Critical Congenital Heart Disease},
journal = {American Journal of Perinatology},
year = {2025},
volume = {42},
number = {05},
pages = {674--682},
doi = {10.1055/a-2416-5637}
}