EUVIMEDEUVIMED entdecken
Crossref

The Influence of Preimplant Balancing on Manipulation under Anesthesia Rates following Imageless Robotic-Assisted Total Knee Arthroplasty

Justin T Butler iD, Samuel D Stegelmann, Trent Davis, Amy Singleton, Hunter Ostlie, Richard Miller, Kirk Davis

The Journal of Knee Surgery · 01.01.2025 · 38 (02) · 053-061

DOI: 10.1055/a-2410-2668 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.01.2025. Verfasst von Justin T Butler und 6 weiteren Autor:innen. Beteiligte Einrichtung: The CORE Institute, Hip and Knee Reconstruction, Phoenix, Arizona. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Anesthesia, Postoperative Complications. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acquired idiopathic stiffness (AIS) following total knee arthroplasty (TKA) often requires manipulation under anesthesia (MUA). Robotic-assisted TKA (RA-TKA) systems provide gap balance templates for objective correlation with the rate of AIS. The purpose of this study was to assess intraoperative balancing parameters that were associated with MUA utilizing an “anatomical” implant design. We performed a retrospective chart review of 265 imageless RA-TKA procedures performed by R.M. and K.D. between 2018 and 2020. The primary outcome for AIS or clinically significant “arthrofibrosis” was MUA. Patient intraoperative gap planning data were examined for association. The rate of MUA was 8.7% (23/265), which was performed at a mean follow-up time of 75.9 ± 32.2 days. The lateral to medial gap difference in extension was significantly less in patients requiring MUA (odds ratio [OR] = 0.86, 95% confidence interval [CI], 0.75–0.99) (p = 0.034). Significantly less preoperative varus mechanical axis was associated with knees requiring MUA (1.83° vs. 4.04°, OR = 1.09, 95% CI, 1.00–1.19). Decreased templated mechanical axis correction was associated with MUA (2.09° vs. 4.75°, p < 0.0001). A tighter lateral-to-medial gap in extension, less preoperative varus, and smaller templated mechanical axis corrections were associated with increased rates of MUA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresAnesthesiaPostoperative ComplicationsHumansRetrospective StudiesMaleAgedFemaleMiddle AgedKnee ProsthesisKnee JointAged, 80 and overProsthesis Design

Autor:innen und Institutionen

  • The CORE Institute, Hip and Knee Reconstruction, Phoenix, Arizona.
  • Department of Orthopaedic Surgery, Medical City Denton, Denton, Texas.
  • Heritage College of Osteopathic Medicine, Ohio University, Athens, Ohio.
  • Department of Orthopaedics, Mercy Health-St. Vincent Medical Center, Toledo, Ohio.
  • Fulton County Health Center, FCHC Orthopedics, Wauseon, Ohio.

ORCID-Profile: Justin T Butler

Zitieren

APA

Butler, J. T., Stegelmann, S. D., Davis, T., Singleton, A., Ostlie, H., Miller, R., & Davis, K. (2025). The Influence of Preimplant Balancing on Manipulation under Anesthesia Rates following Imageless Robotic-Assisted Total Knee Arthroplasty. The Journal of Knee Surgery, 38(02), 053-061. https://doi.org/10.1055/a-2410-2668

Vancouver

Butler JT, Stegelmann SD, Davis T, Singleton A, Ostlie H, Miller R, et al. The Influence of Preimplant Balancing on Manipulation under Anesthesia Rates following Imageless Robotic-Assisted Total Knee Arthroplasty. The Journal of Knee Surgery. 2025;38(02):053-061. doi:10.1055/a-2410-2668

BibTeX
@article{Butler2025,
  author = {Butler, Justin T and Stegelmann, Samuel D and Davis, Trent and Singleton, Amy and Ostlie, Hunter and Miller, Richard and Davis, Kirk},
  title = {The Influence of Preimplant Balancing on Manipulation under Anesthesia Rates following Imageless Robotic-Assisted Total Knee Arthroplasty},
  journal = {The Journal of Knee Surgery},
  year = {2025},
  volume = {38},
  number = {02},
  pages = {053--061},
  doi = {10.1055/a-2410-2668}
}
Kostenlos starten →