The “Flapbot”: A Global Perspective on the Validity and Usability of a Flap Monitoring Chatbot
Journal of Reconstructive Microsurgery · 01.03.2025 · 41 (03) · 227-236
DOI: 10.1055/a-2355-3970 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.03.2025. Verfasst von Hamza Ejaz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Reconstructive Surgery and Regenerative Medicine Research Centre (ReconRegen), Institute of Life Sciences, Swansea University Medical School, Swansea…. Hauptthemen laut MEDLINE: Free Tissue Flaps, Plastic Surgery Procedures, Mobile Applications. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
Background
The Flapbot chatbot assists in free-flap monitoring, emphasizing accessibility, user-friendliness, and global reliability. This study assesses Flapbot's worldwide validity and usability and uses qualitative analysis to identify areas for future enhancement.
Methods
Flapbot, built on Google's DialogFlow, was evaluated by international plastic surgeons. Invitations were sent to the International Lower Limb Reconstruction Collaborative (INTELLECT), International Confederation of Plastic Surgery Societies (ICOPLAST), and the International Microsurgery Club. Out of the 42 surgeons who agreed to participate, 21 tested the Flapbot and completed an online survey on its validity and usability. The survey had 13 validity items and 10 usability items. Data analysis involved computing the individual content validity index (I-CVI) and scale-wide content validity index (S-CVI) for validity, and the system usability score (SUS) for usability. Thematic analysis distilled free-text responses to identify key themes.
Results
Nine of 13 items had an I-CVI over 0.78, denoting significant relevance. The S-CVI score stood at 0.82, indicating high relevance. The SUS score was 68, representing average usability. Themes highlighted issues with the current model, development suggestions, and surgeons' concerns regarding growing reliance on digital tools in health care.
Conclusion
Flapbot is a promising digital aid for free-flap monitoring. While it showcases notable validity and usability, improvements in functionality, usability, and accessibility are needed for broader global use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Reconstructive Surgery and Regenerative Medicine Research Centre (ReconRegen), Institute of Life Sciences, Swansea University Medical School, Swansea, United Kingdom.
- Department of Plastic Surgery, Welsh Centre for Burns and Plastic Surgery, Morriston Hospital, Swansea, United Kingdom.
- Department of Plastic Surgery, The Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle Upon Tyne, England.
- Department of Plastic Surgery, Kellogg College, University of Oxford, Oxford, United Kingdom.
ORCID-Profile: Hamza Ejaz, Stephen R Ali, Juan E Berner
Zitieren
APA
Ejaz, H., Ali, S. R., Berner, J. E., Dobbs, T. D., Whitaker, I. S., & Flapbot Collaborative (2025). The “Flapbot”: A Global Perspective on the Validity and Usability of a Flap Monitoring Chatbot. Journal of Reconstructive Microsurgery, 41(03), 227-236. https://doi.org/10.1055/a-2355-3970
Vancouver
Ejaz H, Ali SR, Berner JE, Dobbs TD, Whitaker IS, Flapbot Collaborative. The “Flapbot”: A Global Perspective on the Validity and Usability of a Flap Monitoring Chatbot. Journal of Reconstructive Microsurgery. 2025;41(03):227-236. doi:10.1055/a-2355-3970
BibTeX
@article{Ejaz2025,
author = {Ejaz, Hamza and Ali, Stephen R and Berner, Juan E and Dobbs, Thomas D and Whitaker, Iain S and Flapbot Collaborative, Flapbot Collaborative},
title = {The “Flapbot”: A Global Perspective on the Validity and Usability of a Flap Monitoring Chatbot},
journal = {Journal of Reconstructive Microsurgery},
year = {2025},
volume = {41},
number = {03},
pages = {227--236},
doi = {10.1055/a-2355-3970}
}
EUVIMED