Mechanical evaluation of the dilation force of dilation devices during interventional endoscopic ultrasound
Endoscopy International Open · 2024-08 · 12 (08) · E955-E961
DOI: 10.1055/a-2351-0647 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, online erschienen am 08.08.2024. Verfasst von Takeshi Ogura und 11 weiteren Autor:innen. Beteiligte Einrichtung: 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Japan. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background and study aims To insert the metal stent delivery system (8.5F) during interventional endoscopic ultrasound (I-EUS), several dilation steps are needed, which may be related to increased bile leakage from a fistula. There have been no definitive studies of dilation force. The aim of the present study was to evaluate dilation force during I-EUS using several dilation devices.
Methods
In the present study, seven dilation devices were evaluated including bougie dilators such as a straight-shaped dilator (the ES dilator, Soehendra dilator, a standard ERCP catheter) a screw-shaped dilator (Tornus ES, Soehendra stent retriever), and a 4-mm balloon catheter (REN biliary balloon catheter, Hurricane RX). The diameter of each dilator and dilation force were measured.
Results
Of the bougie dilators, the dilation force of the ES dilator was the highest (0.908±0.035 kg). Of the balloon catheters, the dilation force of the Hurricane RX (3.261±0.024 kg) was slightly higher than that of the REN (3.159±0.072 kg). Of the bougie dilators, although the diameter of the ES dilator was not larger than that of the Tornus ES, the dilation force was stronger. Similarly, the diameter of the Soehendra stent retriever was greater than that of the ERCP catheter or Soehendra dilator and the dilation force was lower.
Conclusions
Compared with bougie dilators, balloon catheters have stronger dilation force according to our experimental study. The present results should be evaluated in clinical trials.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Japan.
- Department of Business planning, Kaneka Medix Corporation, Osaka, Japan.
ORCID-Profile: Akitoshi Hakoda, Atsushi Okuda
Zitieren
APA
Ogura, T., Ueno, S., Hakoda, A., Okuda, A., Nishioka, N., Sakamoto, J., Yamamura, M., Hattori, N., Bessho, K., Nishikawa, H., Kanaoka, R., & Kurose, Y. (2024). Mechanical evaluation of the dilation force of dilation devices during interventional endoscopic ultrasound. Endoscopy International Open, 12(08), E955-E961. https://doi.org/10.1055/a-2351-0647
Vancouver
Ogura T, Ueno S, Hakoda A, Okuda A, Nishioka N, Sakamoto J, et al. Mechanical evaluation of the dilation force of dilation devices during interventional endoscopic ultrasound. Endoscopy International Open. 2024;12(08):E955-E961. doi:10.1055/a-2351-0647
BibTeX
@article{Ogura2024,
author = {Ogura, Takeshi and Ueno, Saori and Hakoda, Akitoshi and Okuda, Atsushi and Nishioka, Nobu and Sakamoto, Jun and Yamamura, Masahiro and Hattori, Nobuhiro and Bessho, Kimi and Nishikawa, Hiroki and Kanaoka, Rie and Kurose, Youhei},
title = {Mechanical evaluation of the dilation force of dilation devices during interventional endoscopic ultrasound},
journal = {Endoscopy International Open},
year = {2024},
volume = {12},
number = {08},
pages = {E955--E961},
doi = {10.1055/a-2351-0647}
}
EUVIMED