The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 01.04.2025 · 197 (04) · 436-446
DOI: 10.1055/a-2350-0107 ↗Kurz gefasst
Fachartikel in der Zeitschrift RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, erschienen am 01.04.2025. Verfasst von Moritz Konstantin Brandenstein und 8 weiteren Autor:innen. Beteiligte Einrichtung: Radiology, University Hospital Regensburg, Regensburg, Germany. Hauptthemen laut MEDLINE: Thyroid Neoplasms, Multimodal Imaging, Thyroid Nodule. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
V-flow is a dynamic ultrasound technique that visualizes perfusion patterns by displaying dynamic arrows that change in response to the flow of erythrocytes. Furthermore, it provides quantitative values for the maximum and mean velocity of blood flow as well as a percentage value for turbulence. The aim was to enhance the preoperative diagnostic accuracy of thyroid lesions by combining V-flow with established ultrasound modes. B-mode, CCDS, elastography, CEUS, and V-flow were performed on 101 patients. After the ultrasound examination, every nodule was confirmed as benign or malignant via histopathology. The Kruskal–Wallis test, ROC curve, and binary logistic regression were used for the statistical analysis. 93 benign regressive thyroid nodules and 8 carcinomas were included in this study. The average mean velocity value for benign lesions was measured at 19.5 cm/s and at 10.7 cm/s for malignant lesions (p = 0.039). The average turbulence percentage was 26.1% for benign nodules and 46.7% for carcinomas (p = 0.016). Carcinomas exhibited a slower and more turbulent perfusion pattern compared to benign tumors. A V-flow-centered system achieves a sensitivity of 100.0% and a specificity of 84.9% in predicting malignancy. This system could have reduced the number of unnecessary thyroid surgeries for benign lesions in our patient group by 70%. The capillary perfusion of thyroid nodules represents a significant indicator of its status. By analyzing the velocity and turbulence level of microvascular blood flow, V-flow offers promising prospects for accurately distinguishing between benign and malignant thyroid lesions. When integrated into a comprehensive multimodal sonographic imaging approach, V-flow further enhances diagnostic accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Radiology, University Hospital Regensburg, Regensburg, Germany.
- Surgery, University Hospital Regensburg, Regensburg, Germany.
- Nuclear Medicine, University Hospital Regensburg, Regensburg, Germany.
Zitieren
APA
Brandenstein, M. K., Zhang, L., Scharf, G., Thurn, S., Hornung, M., Menhart, K., Meiler, S., Stroszczynski, C., & Jung, E. M. (2025). The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 197(04), 436-446. https://doi.org/10.1055/a-2350-0107
Vancouver
Brandenstein MK, Zhang L, Scharf G, Thurn S, Hornung M, Menhart K, et al. The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 2025;197(04):436-446. doi:10.1055/a-2350-0107
BibTeX
@article{Brandenstein2025,
author = {Brandenstein, Moritz Konstantin and Zhang, Liang and Scharf, Gregor and Thurn, Sylvia and Hornung, Matthias and Menhart, Karin and Meiler, Stefanie and Stroszczynski, Christian and Jung, Ernst Michael},
title = {The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging},
journal = {RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren},
year = {2025},
volume = {197},
number = {04},
pages = {436--446},
doi = {10.1055/a-2350-0107}
}
EUVIMED