EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Visually navigated, ultrasound-guided, freehand percutaneous calyceal puncture – preclinical evaluation of a novel device to simplify a complex surgical task

Gamal Anton Wakileh, Manuel Hohmann, Marie Claire Rassweiler-Seyfried, Jan Thorsten Klein iD

Ultrasound International Open · 15.07.2024 · 10 (CP)

DOI: 10.1055/a-2324-7668 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasound International Open, erschienen am 15.07.2024. Verfasst von Gamal Anton Wakileh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Urology, University Ulm Medical Centre, Ulm, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Freehand sonographic percutaneous puncture techniques for the renal calyceal system are on the rise. Much time and practice are required to master this technique. Navigation-supported puncture aids could help make percutaneous access easier and faster. The aim of this study was to determine whether navigated puncture is feasible, and whether it is easier and faster compared to the conventional sonographic procedure. Materials & Methods We performed prospective free-hand percutaneous puncture on a porcine kidney model embedded in gelatin using the Xperius ultrasound system in combination with needle tracking with a Stimuplex Onvision hollow needle, compared to the conventional freehand ultrasound puncture technique. Punctures were performed by 25 participants using the ultrasound machine with or without needle tracking mode.

Results

Compared to the conventional approach, the navigated approach reduced the number of puncture procedures by 0.2 attempts(8%) in the experienced group. The time to calyx access was reduced by 15 seconds (26%). In the novice group, navigated puncture required 1.2 fewer attempts (36%) and the time to access was 70 seconds faster (61%).

Conclusion

Puncture using the novel device is feasible. The number of punctures and the time needed for successful access of the calyceal system was reduced by use of navigation in both groups, although the trend was significant only in the novice group. Navigation using needle tracking seems to help beginners perform sonographic percutaneous puncture at a level similar to experienced users. For a more precise analysis and validation, further studies are needed.

Schlagwörter

Stichwörter der Autor:innen

PCNLkidney stone surgerynavigationpercutaneous kidney puncturerenal access

Autor:innen und Institutionen

  • Urology, University Ulm Medical Centre, Ulm, Germany.
  • Urology, University Hospital Ulm, Ulm, Germany.
  • Department of Urology and Urological Surgery, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany.
  • Urology, Spital Thurgau AG, Kantonsspital Münsterlingen, Münsterlingen, Switzerland.

ORCID-Profile: Jan Thorsten Klein

Zitieren

APA

Wakileh, G. A., Hohmann, M., Rassweiler-Seyfried, M. C., & Klein, J. T. (2024). Visually navigated, ultrasound-guided, freehand percutaneous calyceal puncture – preclinical evaluation of a novel device to simplify a complex surgical task. Ultrasound International Open, 10(CP). https://doi.org/10.1055/a-2324-7668

Vancouver

Wakileh GA, Hohmann M, Rassweiler-Seyfried MC, Klein JT. Visually navigated, ultrasound-guided, freehand percutaneous calyceal puncture – preclinical evaluation of a novel device to simplify a complex surgical task. Ultrasound International Open. 2024;10(CP). doi:10.1055/a-2324-7668

BibTeX
@article{Wakileh2024,
  author = {Wakileh, Gamal Anton and Hohmann, Manuel and Rassweiler-Seyfried, Marie Claire and Klein, Jan Thorsten},
  title = {Visually navigated, ultrasound-guided, freehand percutaneous calyceal puncture – preclinical evaluation of a novel device to simplify a complex surgical task},
  journal = {Ultrasound International Open},
  year = {2024},
  volume = {10},
  number = {CP},
  doi = {10.1055/a-2324-7668}
}
Kostenlos starten →