Computer Patient-Specific 3D Modeling and Custom-Made Guides for Revision ACL Surgery
The Journal of Knee Surgery · 01.09.2024 · 37 (11) · 804-811
DOI: 10.1055/a-2315-7873 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.09.2024. Verfasst von Armando Del Prete und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, University of Florence, Florence, Italy. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament Reconstruction, Reoperation, Tomography, X-Ray Computed, Printing, Three-Dimensional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
Revision anterior cruciate ligament reconstruction (ACLR) is a challenging surgery occurring in 3 to 24% of primary reconstructions. A meticulous planning to study the precise size and location of both femoral and tibial bone tunnels is mandatory. The aim of the study was to evaluate the intra- and interoperator differences in the decision-making process between experienced surgeons after they were asked to make preoperative planning for ACL revision reconstruction with the use of both the computed tomography (CT) scan and a three-dimensional (3D)-printed model of the knee. Data collected from 23 consecutive patients undergoing revision of ACLR for graft failure at a single institute between September 2018 and February 2020 were prospectively reviewed. The double-blinded collected data were presented to three board-certificate attending surgeons. Surgeons were asked to decide whether to perform one-stage or two-stage revision ACLR based on the evaluation of the CT scan images and the 3D-printed custom-made models at two different rounds, T0 and T1, respectively, 7 days apart one from the other. Interoperator consensus following technical mistake was 52% at T0 and 56% at T1 using the CT scans, meanwhile concordance was 95% at T0 and 94% at T1 using the 3D models. Concordance between surgeons following new knee injury was 66% at T0 and 70% at T1 using CT scans, while concordance was 96% both at T0 and T1 using 3D models. Intraoperative variability using 3D models was extremely low: concordance at T0 and T1 was 98%. McNemar test showed a statistical significance in the use of 3D model for preoperative planning (p < 0.005). 3D-printed model reliability resulted to be higher compared with CT as intraoperator surgery technique selection was not modified throughout time from T0 to T1 (p < 0.005). The use of 3D-printed models had the most impact when evaluating femoral and tibial tunnels, resulting to be a useful instrument during preoperative planning of revision ACLR between attending surgeons with medium-high workflow.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, University of Florence, Florence, Italy.
ORCID-Profile: Filippo Leggieri
Zitieren
APA
Del Prete, A., Franco, P., Innocenti, M., Matassi, F., Leggieri, F., Sagliocco, R. J., & Civinini, R. (2024). Computer Patient-Specific 3D Modeling and Custom-Made Guides for Revision ACL Surgery. The Journal of Knee Surgery, 37(11), 804-811. https://doi.org/10.1055/a-2315-7873
Vancouver
Del Prete A, Franco P, Innocenti M, Matassi F, Leggieri F, Sagliocco RJ, et al. Computer Patient-Specific 3D Modeling and Custom-Made Guides for Revision ACL Surgery. The Journal of Knee Surgery. 2024;37(11):804-811. doi:10.1055/a-2315-7873
BibTeX
@article{DelPrete2024,
author = {Del Prete, Armando and Franco, Piero and Innocenti, Matteo and Matassi, Fabrizio and Leggieri, Filippo and Sagliocco, Rosario Jr and Civinini, Roberto},
title = {Computer Patient-Specific 3D Modeling and Custom-Made Guides for Revision ACL Surgery},
journal = {The Journal of Knee Surgery},
year = {2024},
volume = {37},
number = {11},
pages = {804--811},
doi = {10.1055/a-2315-7873}
}
EUVIMED