Endoscopic ultrasound-guided hepaticogastrostomy stent exchange using a novel spiral plastic stent
Endoscopy · 01.12.2024 · 56 (S 01 S 01) · E426-E427
DOI: 10.1055/a-2307-7866 ↗Kurz gefasst
Fallbericht in der Zeitschrift Endoscopy, erschienen am 01.12.2024. Verfasst von Takeshi Ogura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Endoscopy Center, Osaka Medical and Pharmaceutical University Hospital, Takatsuki, Japan. Hauptthemen laut MEDLINE: Endosonography, Stents. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) can be attempted for patients with failed endoscopic retrograde cholangiopancreatography [ 1 ] [ 2 ]. EUS-HGS has recently become indicated for not only malignant biliary obstruction, but also benign biliary disease [ 3 ] [ 4 ]. In benign biliary disease, a self-expandable metal stent (SEMS) might not be suitable, because stent removal may be challenging if the duration of stent deployment is prolonged. Therefore, a plastic stent is usually used. According to a previous study, regular stent exchange may have a clinical impact on prevention of benign biliary disease [ 4 ]. However, flaps are provided at the distal end in most plastic stents to prevent stent dislocation. Unlike the common bile duct, the intrahepatic bile duct has side branches; therefore, during stent removal, the flaps may become stuck in the side branches. Consequently, a plastic stent with flaps has a risk of rupture, as previously described [ 5 ]. To improve stent removability, a spiral-shaped plastic stent has been designed and is available in Japan (Gadelius Medical Co., Ltd, Tokyo, Japan) ([ Fig. 1 ]). This stent has no side flaps; therefore, stent removal through EUS-HGS can be easily performed without the stent flaps becoming stuck in the bile duct side branches. To prevent stent dislocation, the distal end is spiral in shape, and to prevent stent migration, the proximal end is a pigtail shape. A case of successful EUS-HGS stent exchange using this novel plastic stent is reported. Fig. 1 A spiral-shaped plastic stent (Gadelius Medical Co., Ltd, Tokyo, Japan). An 88-year-old woman was admitted because of obstructive jaundice caused by a hepaticojejunostomy stricture. In addition, a huge intrahepatic bile duct stone was present. She first underwent EUS-HGS using SEMS, and because of her advanced age, only stent exchange to a spiral-shaped plastic stent was performed ([ Fig. 2 ]). After 6 months, she was admitted again for stent exchange. First, a standard duodenoscope was inserted into the stomach. Then, after a guidewire was deployed beside the stent ([ Fig. 3 ]), stent removal using grasping forceps was attempted. As the stent had no side flaps, stent removal was easily performed without stent rupture ([ Fig. 4 ]). After evaluation of the biliary system, a spiral-shaped plastic stent was deployed without any adverse events ([ Fig. 5 ], [ Video 1 ]). Fig. 2 The spiral-shaped plastic stent was deployed as an endoscopic ultrasound-guided hepaticogastrostomy stent. Fig. 3 A guidewire was deployed beside the stent. Fig. 4 As the stent had no side flaps, stent removal was easily performed without stent rupture. Fig. 5 The spiral-shaped plastic stent was deployed. Quality: mobile 360 480 720 Download Removal of an endoscopic ultrasound-guided hepaticogastrostomy stent was attempted. As this stent had no side flaps, removal was easily performed without stent rupture.Video 1 In conclusion, a spiral-shaped plastic stent may be useful as an EUS-HGS stent for patients who undergo scheduled stent exchange because of its easy removability. Endoscopy_UCTN_Code_TTT_1AS_2AH Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 17 May 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Endoscopy Center, Osaka Medical and Pharmaceutical University Hospital, Takatsuki, Japan.
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Japan.
ORCID-Profile: Atsushi Okuda
Zitieren
APA
Ogura, T., Okuda, A., Ueno, S., Nishioka, N., & Nishikawa, H. (2024). Endoscopic ultrasound-guided hepaticogastrostomy stent exchange using a novel spiral plastic stent. Endoscopy, 56(S 01 S 01), E426-E427. https://doi.org/10.1055/a-2307-7866
Vancouver
Ogura T, Okuda A, Ueno S, Nishioka N, Nishikawa H. Endoscopic ultrasound-guided hepaticogastrostomy stent exchange using a novel spiral plastic stent. Endoscopy. 2024;56(S 01 S 01):E426-E427. doi:10.1055/a-2307-7866
BibTeX
@article{Ogura2024,
author = {Ogura, Takeshi and Okuda, Atsushi and Ueno, Saori and Nishioka, Nobu and Nishikawa, Hiroki},
title = {Endoscopic ultrasound-guided hepaticogastrostomy stent exchange using a novel spiral plastic stent},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 01 S 01},
pages = {E426--E427},
doi = {10.1055/a-2307-7866}
}