EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Comparing Fetal Ultrasound Biometric Measurements to Neonatal Anthropometry at the Extremes of Birth Weight

Jessica L Gleason iD, Mary L Hediger, Zhen Chen, Jagteshwar Grewal, Roger Newman, William A Grobman, John Owen, Katherine L Grantz

American Journal of Perinatology · 01.11.2024 · 41 (15) · 2125-2134

DOI: 10.1055/a-2298-5245 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Perinatology, erschienen am 01.11.2024. Verfasst von Jessica L Gleason und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Population Health Research, Division of Intramural Research, Epidemiology Branch, Eunice Kennedy Shriver National Institute of Child Heal…. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Birth Weight, Gestational Age, Fetal Weight. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NICHD NIH HHS, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Intramural NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Error in birthweight prediction by sonographic estimated fetal weight (EFW) has clinical implications, such as avoidable cesarean or misclassification of fetal risk in labor. We aimed to evaluate optimal timing of ultrasound and which fetal measurements contribute to error in fetal ultrasound estimations of birth size at the extremes of birthweight. Study Design We compared differences in head circumference (HC), abdominal circumference (AC), femur length, and EFW between ultrasound and corresponding birth measurements within 14 (n = 1,290) and 7 (n = 617) days of birth for small- (SGA, 90th) newborns.

Results

Average differences between EFW and birthweight for SGA neonates were: −40.2 g (confidence interval [CI]: −82.1, 1.6) at 14 days versus 13.6 g (CI: −52.4, 79.7) at 7 days; for AGA, −122.4 g (−139.6, −105.1) at 14 days versus −27.2 g (−50.4, −4.0) at 7 days; and for LGA, −242.8 g (−306.5, −179.1) at 14 days versus −72.1 g (−152.0, 7.9) at 7 days. Differences between fetal and neonatal HC were larger at 14 versus 7 days, and similar to patterns for EFW and birthweight, differences were the largest for LGA at both intervals. In contrast, differences between fetal and neonatal AC were larger at 7 versus 14 days, suggesting larger error in AC estimation closer to birth.

Conclusion

Using a standardized ultrasound protocol, SGA neonates had ultrasound measurements closer to actual birth measurements compared with AGA or LGA neonates. LGA neonates had the largest differences between fetal and neonatal size, with measurements 14 days from delivery showing 3- to 4-fold greater differences from birthweight. Differences in EFW and birthweight may not be explained by a single fetal measurement; whether estimation may be improved by incorporation of other knowable factors should be evaluated in future research. Key Points

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, PrenatalBirth WeightGestational AgeFetal WeightAnthropometryInfant, Small for Gestational AgeBiometryHumansInfant, NewbornFemalePregnancyMaleFemurAdultHeadAbdomen

Autor:innen und Institutionen

  • Division of Population Health Research, Division of Intramural Research, Epidemiology Branch, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, Maryland.
  • Division of Population Health Research, Division of Intramural Research, Biostatistics and Bioinformatics Branch, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, Maryland.
  • Division of Population Health Research, Division of Intramural Research, Office of the Director, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda,…
  • Department of Obstetrics and Gynecology, Medical University of South Carolina, Charleston, South Carolina.
  • Department of Obstetrics and Gynecology, The Ohio State University, Columbus, Ohio.
  • Department of Obstetrics and Gynecology, University of Alabama at Birmingham, Birmingham, Alabama.

ORCID-Profile: Jessica L Gleason

Förderung

  • NICHD NIH HHS
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development
  • Intramural NIH HHS
  • NIH HHS
  • U.S. Department of Health and Human Services
  • National Institutes of Health

Zitieren

APA

Gleason, J. L., Hediger, M. L., Chen, Z., Grewal, J., Newman, R., Grobman, W. A., Owen, J., & Grantz, K. L. (2024). Comparing Fetal Ultrasound Biometric Measurements to Neonatal Anthropometry at the Extremes of Birth Weight. American Journal of Perinatology, 41(15), 2125-2134. https://doi.org/10.1055/a-2298-5245

Vancouver

Gleason JL, Hediger ML, Chen Z, Grewal J, Newman R, Grobman WA, et al. Comparing Fetal Ultrasound Biometric Measurements to Neonatal Anthropometry at the Extremes of Birth Weight. American Journal of Perinatology. 2024;41(15):2125-2134. doi:10.1055/a-2298-5245

BibTeX
@article{Gleason2024,
  author = {Gleason, Jessica L and Hediger, Mary L and Chen, Zhen and Grewal, Jagteshwar and Newman, Roger and Grobman, William A and Owen, John and Grantz, Katherine L},
  title = {Comparing Fetal Ultrasound Biometric Measurements to Neonatal Anthropometry at the Extremes of Birth Weight},
  journal = {American Journal of Perinatology},
  year = {2024},
  volume = {41},
  number = {15},
  pages = {2125--2134},
  doi = {10.1055/a-2298-5245}
}
Kostenlos starten →