Ultrasound-Guided Modified Thread Carpal Tunnel Release for Carpal Tunnel Syndrome: A Pilot Study

Jaewon Kim, Jae Min Kim iD, Hae-Yeon Park, In Jong Kim

Ultraschall in der Medizin - European Journal of Ultrasound · 01.02.2025 · 46 (01) · 57-65

DOI: 10.1055/a-2280-3507 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultraschall in der Medizin - European Journal of Ultrasound, erschienen am 01.02.2025. Verfasst von Jaewon Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Carpal Tunnel Syndrome, Ultrasonography, Interventional. Die Arbeit nennt 30 Literaturangaben. Gefördert von: National Research Foundation of Korea (NRF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to investigate the effectiveness and safety of modified thread carpal tunnel release (mTCTR) using Smartwire-01 in patients with carpal tunnel syndrome (CTS). Materials and Methods Patients with CTS who required CTR were enrolled. Symptom severity and functional status were assessed using the Boston Carpal Tunnel Syndrome Questionnaire-Symptom Severity Scale (BCTQ-SSS) and Functional Status Scale (BCTQ-FSS), and pain was assessed using a numerical rating scale (NRS) at 4, 8, and 12 weeks after mTCTR. The scores were compared with the pre-procedural scores. The electrophysiologic study and median nerve cross-sectional area (CSA) measurements at the wrist before and 12 weeks after mTCTR were compared.

Results

A total of 11 patients were included. No adverse effects were reported throughout the study period. The NRS, BCTQ-SSS, and BCTQ-FSS scores significantly improved at 4 weeks after mTCTR, and this improvement persisted throughout the follow-up period (NRS and BCTQ-SSS, P < 0.001; BCTQ-FSS, P = 0.012). After 12 weeks, the latency and velocity of the median sensory nerve action potential significantly improved, compared with those before mTCTR (latency, 5.4 ± 1.3 to 4.7 ± 1.1 ms, P = 0.01; velocity 27.8 ± 6.8 to 31.8 ± 7.4 m/s, P = 0.019). No significant change was observed in the median nerve CSA before and after mTCTR. Conclusion mTCTR using Smartwire-01 is a safe and effective procedure and a possible alternative to surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carpal Tunnel SyndromeUltrasonography, InterventionalHumansMalePilot ProjectsFemaleMiddle AgedMedian NerveAdultAgedPain MeasurementFollow-Up Studies

Autor:innen und Institutionen

  • Department of Rehabilitation Medicine, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Department of Rehabilitation Medicine, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Department of Rehabilitation Medicine, Howareyou Rehabilitation Clinic, Seoul, Republic of Korea.

ORCID-Profile: Jae Min Kim

Förderung

  • National Research Foundation of Korea (NRF)

Zitieren

APA

Kim, J., Kim, J. M., Park, H. Y., & Kim, I. J. (2025). Ultrasound-Guided Modified Thread Carpal Tunnel Release for Carpal Tunnel Syndrome: A Pilot Study. Ultraschall in der Medizin - European Journal of Ultrasound, 46(01), 57-65. https://doi.org/10.1055/a-2280-3507

Vancouver

Kim J, Kim JM, Park HY, Kim IJ. Ultrasound-Guided Modified Thread Carpal Tunnel Release for Carpal Tunnel Syndrome: A Pilot Study. Ultraschall in der Medizin - European Journal of Ultrasound. 2025;46(01):57-65. doi:10.1055/a-2280-3507

BibTeX
@article{Kim2025,
  author = {Kim, Jaewon and Kim, Jae Min and Park, Hae-Yeon and Kim, In Jong},
  title = {Ultrasound-Guided Modified Thread Carpal Tunnel Release for Carpal Tunnel Syndrome: A Pilot Study},
  journal = {Ultraschall in der Medizin - European Journal of Ultrasound},
  year = {2025},
  volume = {46},
  number = {01},
  pages = {57--65},
  doi = {10.1055/a-2280-3507}
}
Kostenlos starten →