EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla

Fabrice Caillol iD, Sébastien Godat, Alexey Solovyev iD, Amina Harouchi, Sarra Oumrani, Mariola Marx, Solene Hoibian, Yanis Dahel, Jean-Philippe Ratone, Marc Giovannini

Endoscopy International Open · 2024-03 · 12 (03) · E377-E384

DOI: 10.1055/a-2261-2968 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy International Open, online erschienen am 07.03.2024. Verfasst von Fabrice Caillol und 9 weiteren Autor:innen. Beteiligte Einrichtung: Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and study aims In cases of inaccessible papilla, EUS-guided biliary drainage (EUS-BD) has been described as an alternative to calibrate benign biliary stenosis. However, few studies are available. Patients and methods This tw-center, retrospective study was designed to evaluate technical success and clinical success at 1 year. All patients who underswent EUS-BD without the rendezvous technique used for calibration of benign biliary stenosis were included from 2016 to 2022. Patients underwent EUS-hepaticogastrostomy (EUS-HGS) during the first session. Then, HGS was used to access the bile duct, allowing calibration of the stenosis: Dilation of the biliary stenosis and placement of double pigtail stents through the stenosis for 1 year.

Results

Thirty-six patients were included. Technical success was 89% (32/36), with four failures to cross the stenosis but EUS-HGS was performed in 100% of the cases. Nine patients were excluded during calibration because of oncological relapse in six and complex stenosis in three. Three patients had not yet reached 1 year of follow-up. Twenty patients had a calibration for at least 1 year. Clinical success after stent placement was considered in all cases after 1 year of follow-up. Thirteen patients underwent stent removal and no relapse occurred after 435 days of follow-up (SD=568). Global morbidity was 41.7% (15/36) with only one serious complication (needing intensive care), including seven cases of cholangitis due to intrabiliary duct obstruction and five stent migrations. No deaths were reported.

Conclusions

EUS-BD for calibration in case of benign biliary stenosis is an option. Dedicated materials are needed to decrease morbidity.

Schlagwörter

Stichwörter der Autor:innen

Biliary tractEndoscopic ultrasonographyIntervention EUSPancreatobiliary (ERCP/PTCD)Strictures

Autor:innen und Institutionen

  • Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France.
  • gastroentérologie, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland.
  • Statistics Unit, Paoli-Calmettes Institute, Marseille, France.
  • Gastroenterology and Hepatology, CHUV, Lausanne, Switzerland.
  • Gastroenterology Unit, Paoli-Calmettes Institute, Marseille, France.
  • UEMCO, Paoli-Calmettes Institute, Marseille, France.

ORCID-Profile: Fabrice Caillol, Alexey Solovyev

Zitieren

APA

Caillol, F., Godat, S., Solovyev, A., Harouchi, A., Oumrani, S., Marx, M., Hoibian, S., Dahel, Y., Ratone, J. P., & Giovannini, M. (2024). EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla. Endoscopy International Open, 12(03), E377-E384. https://doi.org/10.1055/a-2261-2968

Vancouver

Caillol F, Godat S, Solovyev A, Harouchi A, Oumrani S, Marx M, et al. EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla. Endoscopy International Open. 2024;12(03):E377-E384. doi:10.1055/a-2261-2968

BibTeX
@article{Caillol2024,
  author = {Caillol, Fabrice and Godat, Sébastien and Solovyev, Alexey and Harouchi, Amina and Oumrani, Sarra and Marx, Mariola and Hoibian, Solene and Dahel, Yanis and Ratone, Jean-Philippe and Giovannini, Marc},
  title = {EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla},
  journal = {Endoscopy International Open},
  year = {2024},
  volume = {12},
  number = {03},
  pages = {E377--E384},
  doi = {10.1055/a-2261-2968}
}
Kostenlos starten →