EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla
Endoscopy International Open · 2024-03 · 12 (03) · E377-E384
DOI: 10.1055/a-2261-2968 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, online erschienen am 07.03.2024. Verfasst von Fabrice Caillol und 9 weiteren Autor:innen. Beteiligte Einrichtung: Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background and study aims In cases of inaccessible papilla, EUS-guided biliary drainage (EUS-BD) has been described as an alternative to calibrate benign biliary stenosis. However, few studies are available. Patients and methods This tw-center, retrospective study was designed to evaluate technical success and clinical success at 1 year. All patients who underswent EUS-BD without the rendezvous technique used for calibration of benign biliary stenosis were included from 2016 to 2022. Patients underwent EUS-hepaticogastrostomy (EUS-HGS) during the first session. Then, HGS was used to access the bile duct, allowing calibration of the stenosis: Dilation of the biliary stenosis and placement of double pigtail stents through the stenosis for 1 year.
Results
Thirty-six patients were included. Technical success was 89% (32/36), with four failures to cross the stenosis but EUS-HGS was performed in 100% of the cases. Nine patients were excluded during calibration because of oncological relapse in six and complex stenosis in three. Three patients had not yet reached 1 year of follow-up. Twenty patients had a calibration for at least 1 year. Clinical success after stent placement was considered in all cases after 1 year of follow-up. Thirteen patients underwent stent removal and no relapse occurred after 435 days of follow-up (SD=568). Global morbidity was 41.7% (15/36) with only one serious complication (needing intensive care), including seven cases of cholangitis due to intrabiliary duct obstruction and five stent migrations. No deaths were reported.
Conclusions
EUS-BD for calibration in case of benign biliary stenosis is an option. Dedicated materials are needed to decrease morbidity.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France.
- gastroentérologie, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland.
- Statistics Unit, Paoli-Calmettes Institute, Marseille, France.
- Gastroenterology and Hepatology, CHUV, Lausanne, Switzerland.
- Gastroenterology Unit, Paoli-Calmettes Institute, Marseille, France.
- UEMCO, Paoli-Calmettes Institute, Marseille, France.
ORCID-Profile: Fabrice Caillol, Alexey Solovyev
Zitieren
APA
Caillol, F., Godat, S., Solovyev, A., Harouchi, A., Oumrani, S., Marx, M., Hoibian, S., Dahel, Y., Ratone, J. P., & Giovannini, M. (2024). EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla. Endoscopy International Open, 12(03), E377-E384. https://doi.org/10.1055/a-2261-2968
Vancouver
Caillol F, Godat S, Solovyev A, Harouchi A, Oumrani S, Marx M, et al. EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla. Endoscopy International Open. 2024;12(03):E377-E384. doi:10.1055/a-2261-2968
BibTeX
@article{Caillol2024,
author = {Caillol, Fabrice and Godat, Sébastien and Solovyev, Alexey and Harouchi, Amina and Oumrani, Sarra and Marx, Mariola and Hoibian, Solene and Dahel, Yanis and Ratone, Jean-Philippe and Giovannini, Marc},
title = {EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla},
journal = {Endoscopy International Open},
year = {2024},
volume = {12},
number = {03},
pages = {E377--E384},
doi = {10.1055/a-2261-2968}
}
EUVIMED